In this article, we show experimental results of time-resolved optical spectroscopy performed with small distance between launching and detecting fibers. It was already demonstrated that depth discrimination is independent of source-detector separation and that measurements at small sourcedetector distance provide better contrast and spatial resolution. The main disadvantage is represent by the huge increase in early photons (scarcely diffused by tissue) peak that can saturate the dynamic range of most detectors, hiding information carried by late photons. Thanks to a fast-gated Single- Photon Avalanche Diode (SPAD) module, we are able to reject the peak of early photons and to obtain high-dynamic range acquisitions. We exploit fast-gated SPAD module to perform for the first time functional near-infrared spectroscopy (fNIRS) at small source-detector distance for in vivo measurements and we demonstrate the possibility to detect non-invasively the dynamics of oxygenated and deoxygenated haemoglobin occurring in the motor cortex during a motor task. We also show the improvement in terms of signal amplitude and Signal-to-Noise Ratio (SNR) obtained exploiting fastgated SPAD performances with respect to “non-gated” measurements.

Functional near-infrared spectroscopy at small source-detector distance by means of high dynamic-range fast-gated SPAD acquisitions: First in-vivo measurements

DI SIENO, LAURA;CONTINI, DAVIDE;DALLA MORA, ALBERTO;TORRICELLI, ALESSANDRO;SPINELLI, LORENZO;CUBEDDU, RINALDO;TOSI, ALBERTO;BOSO, GIANLUCA;PIFFERI, ANTONIO GIOVANNI
2013-01-01

Abstract

In this article, we show experimental results of time-resolved optical spectroscopy performed with small distance between launching and detecting fibers. It was already demonstrated that depth discrimination is independent of source-detector separation and that measurements at small sourcedetector distance provide better contrast and spatial resolution. The main disadvantage is represent by the huge increase in early photons (scarcely diffused by tissue) peak that can saturate the dynamic range of most detectors, hiding information carried by late photons. Thanks to a fast-gated Single- Photon Avalanche Diode (SPAD) module, we are able to reject the peak of early photons and to obtain high-dynamic range acquisitions. We exploit fast-gated SPAD module to perform for the first time functional near-infrared spectroscopy (fNIRS) at small source-detector distance for in vivo measurements and we demonstrate the possibility to detect non-invasively the dynamics of oxygenated and deoxygenated haemoglobin occurring in the motor cortex during a motor task. We also show the improvement in terms of signal amplitude and Signal-to-Noise Ratio (SNR) obtained exploiting fastgated SPAD performances with respect to “non-gated” measurements.
2013
Neurophotonics
978-0-8194-9812-0
Functional near-infrared spectroscopy (fNIRS); Turbid media; Short source-detector distance; Single-Photon Avalanche Diode; Time-Correlated Single-Photon Counting (TCSPC); Time-resolved spectroscopy; sezele
File in questo prodotto:
File Dimensione Formato  
880402.pdf

Accesso riservato

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 296.73 kB
Formato Adobe PDF
296.73 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/734369
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 5
social impact