The transient model of 3-phase diode bridge rectifiers is developed, and the implementation of the operation analytical equations is carried out, by means of a switching functions Park formulation. A few examples show effectiveness and usefulness of the adopted approach: at first, a 6-pulse bridge rectifier is examined; later, a 12-pulse system is studied, both with series and parallel connected bridges.
Analytical Model and Implementation by Equations of Three-Phase Diode Bridge Rectifiers Operation
DI GERLANDO, ANTONINO;FOGLIA, GIOVANNI MARIA;IACCHETTI, MATTEO FELICE;PERINI, ROBERTO
2010-01-01
Abstract
The transient model of 3-phase diode bridge rectifiers is developed, and the implementation of the operation analytical equations is carried out, by means of a switching functions Park formulation. A few examples show effectiveness and usefulness of the adopted approach: at first, a 6-pulse bridge rectifier is examined; later, a 12-pulse system is studied, both with series and parallel connected bridges.File in questo prodotto: