Frequency and phase of the power grid, which are critical for reliable control and protection of grid-tied devices, are generally detected by the closed-loop phase locked-loop (PLL). In highly inductive high-voltage transmission systems, decaying DC (DDC) components with large amplitude can be easily introduced by load disturbances and/or grid abnormalities, leading to severe performance degradation of the PLL during the transient. Focusing on this issue, in this paper, modifications to the conventional synchronous reference frame (SRF)-PLL have been made to address the short-term disturbances including the DDC component, and the system operation is divided into the normal state and the DDC-transient state. The SRF-PLL is only adopted for the normal state where the DDC component is negligible. In the presence of a significant DDC component, as well as disturbances including negative-/zero-sequence components and harmonics, the weak effectiveness of the conventional SRF-PLL is proved, and an efficient DDC component extraction method, with a detection time of 0.5 grid cycle, is introduced for the three-phase system. The real-time amplitude and phase of the positive-sequence component can be efficiently extracted via the proposed scheme, by exploiting the transient signal properties in the dq-frame and assuming a constant grid frequency during the short transient. Finally, a proper design of switching logic has been proposed to allow for the fast and precise transition between the normal and the DDC-transient state, thereby ensuring high steady-state accuracy as well as short-term DDC transient immunity. Hardware-in-the-loop based experiments have been used to verify the effectiveness of the proposed PLL technique.

Phase locked-loop with decaying DC transient removal for three-phase grids

Liu X.;
2022-01-01

Abstract

Frequency and phase of the power grid, which are critical for reliable control and protection of grid-tied devices, are generally detected by the closed-loop phase locked-loop (PLL). In highly inductive high-voltage transmission systems, decaying DC (DDC) components with large amplitude can be easily introduced by load disturbances and/or grid abnormalities, leading to severe performance degradation of the PLL during the transient. Focusing on this issue, in this paper, modifications to the conventional synchronous reference frame (SRF)-PLL have been made to address the short-term disturbances including the DDC component, and the system operation is divided into the normal state and the DDC-transient state. The SRF-PLL is only adopted for the normal state where the DDC component is negligible. In the presence of a significant DDC component, as well as disturbances including negative-/zero-sequence components and harmonics, the weak effectiveness of the conventional SRF-PLL is proved, and an efficient DDC component extraction method, with a detection time of 0.5 grid cycle, is introduced for the three-phase system. The real-time amplitude and phase of the positive-sequence component can be efficiently extracted via the proposed scheme, by exploiting the transient signal properties in the dq-frame and assuming a constant grid frequency during the short transient. Finally, a proper design of switching logic has been proposed to allow for the fast and precise transition between the normal and the DDC-transient state, thereby ensuring high steady-state accuracy as well as short-term DDC transient immunity. Hardware-in-the-loop based experiments have been used to verify the effectiveness of the proposed PLL technique.
2022
ELETTRICI
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0142061522005099-main.pdf

Accesso riservato

Descrizione: Articolo principale
: Publisher’s version
Dimensione 2.78 MB
Formato Adobe PDF
2.78 MB Adobe PDF   Visualizza/Apri
IJEPES_DDC.pdf

accesso aperto

Descrizione: Articolo principale
: Pre-Print (o Pre-Refereeing)
Dimensione 1.93 MB
Formato Adobe PDF
1.93 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1221096
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 14
social impact