Active constraint (AC)/virtual fixture (VF) is among the most popular approaches towards the shared execution of subtasks by the surgeon and robotic systems. As more possibilities appear for the implementation of ACs in surgical scenarios, the need to introduce methods that guarantee a safe and intuitive user-interaction increases. The presence of the human in the loop adds a layer of interactivity and adaptability that renders the assessment of such methods non-trivial. In most works, guidance ACs have been evaluated mainly in terms of enhancement of accuracy and completion time with little regard for other aspects such as human factors, even though the continuous engagement of these methods can considerably degrade the user experience. This paper proposes a set of performance metrics and considerations that can help evaluate guidance ACs with reference to accuracy enhancement, force characteristics and subjective aspects. The use of these metrics is demonstrated through two sets of experiments on 12 surgeons and 6 inexperienced users.

Performance metrics for guidance active constraints in surgical robotics

Enayati, Nima;Ferrigno, Giancarlo;De Momi, Elena
2018-01-01

Abstract

Active constraint (AC)/virtual fixture (VF) is among the most popular approaches towards the shared execution of subtasks by the surgeon and robotic systems. As more possibilities appear for the implementation of ACs in surgical scenarios, the need to introduce methods that guarantee a safe and intuitive user-interaction increases. The presence of the human in the loop adds a layer of interactivity and adaptability that renders the assessment of such methods non-trivial. In most works, guidance ACs have been evaluated mainly in terms of enhancement of accuracy and completion time with little regard for other aspects such as human factors, even though the continuous engagement of these methods can considerably degrade the user experience. This paper proposes a set of performance metrics and considerations that can help evaluate guidance ACs with reference to accuracy enhancement, force characteristics and subjective aspects. The use of these metrics is demonstrated through two sets of experiments on 12 surgeons and 6 inexperienced users.
2018
Computer assisted surgery; Haptics; Human-machine interfaces; Telesurgery; Surgery; Biophysics; Computer Science Applications1707 Computer Vision and Pattern Recognition
File in questo prodotto:
File Dimensione Formato  
rcs1873.pdf

Open Access dal 02/01/2019

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 838.61 kB
Formato Adobe PDF
838.61 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1040268
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact