The structures of the three rings of the stadium "Giuseppe Meazza" in Milan, built in different stages from 1926 until 1990, is a remarkable evidence of the use of reinforced and prestressed concrete in the last century. If, on the one hand, these structures represent an icon for the potential of this material, on the other hand they also highlight its vulnerability. Reinforced concrete structures of the first and second rings are more than 60 years old and suffer from the effects of corrosion of the steel reinforcement. The municipality of Milan, being the owner of the stadium, has set up a collaboration with Politecnico di Milano aimed at the assessment of the conservation condition of the structures and planning of remedial works necessary to preserve and, at the same time, ensure the correct use of this important infrastructure. This paper describes the investigations carried out on the structures of the first and second ring (dating to 1926-37 and 1955 respectively), which allowed the definition of the extension of carbonation of concrete and the state of corrosion of the reinforcement. The opportunity to monitor the progress of the reinforcement corrosion was also highlighted in order to plan repair works. For this purpose, a monitoring system based on probes for measuring the corrosion potential of the reinforcement and electrical resistivity of concrete is under development.

Corrosione delle armature in calcestruzzo armato allo stadio G. Meazza di Milano - Il monitoraggio delle strutture del primo e del secondo anello

BERTOLINI, LUCA;GASTALDI, MATTEO MARIA;
2015-01-01

Abstract

The structures of the three rings of the stadium "Giuseppe Meazza" in Milan, built in different stages from 1926 until 1990, is a remarkable evidence of the use of reinforced and prestressed concrete in the last century. If, on the one hand, these structures represent an icon for the potential of this material, on the other hand they also highlight its vulnerability. Reinforced concrete structures of the first and second rings are more than 60 years old and suffer from the effects of corrosion of the steel reinforcement. The municipality of Milan, being the owner of the stadium, has set up a collaboration with Politecnico di Milano aimed at the assessment of the conservation condition of the structures and planning of remedial works necessary to preserve and, at the same time, ensure the correct use of this important infrastructure. This paper describes the investigations carried out on the structures of the first and second ring (dating to 1926-37 and 1955 respectively), which allowed the definition of the extension of carbonation of concrete and the state of corrosion of the reinforcement. The opportunity to monitor the progress of the reinforcement corrosion was also highlighted in order to plan repair works. For this purpose, a monitoring system based on probes for measuring the corrosion potential of the reinforcement and electrical resistivity of concrete is under development.
2015
Reinforced concrete, corrosion, carbonation, preservation, monitoring
File in questo prodotto:
File Dimensione Formato  
2015_Structural-San Siro.pdf

Open Access dal 01/08/2016

: Publisher’s version
Dimensione 1 MB
Formato Adobe PDF
1 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/983434
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact