A masonry chimney 50 meters high, severely damaged by the May 2012 Emilia-Romagna (Italy) seismic sequence is numerically analyzed by means of non linear static and dynamic FE techniques. The state of damage on the upper part of the structure led to take the decision to shorten the chimney for security reasons, with a reduction of the height up to 37 meters. A modal pushover analysis (MPA) where force distributions based on the principal vibration modes is used to analyze the structure, finding for the 50 meters case crack patterns consistent with the observed ones. In addition, it is shown how, before and after shortening, the behavior factor to be used in modal response spectrum analyses, estimated directly from the MPA results, is slightly higher than unity, indicating a very low dissipative capacity. To validate static approach results, non-linear dynamic analyses are carried out using natural accelerograms and for the masonry material a damage-plasticity model. The residual deformations obtained and the crack patterns found exhibit convincing similarities with the real behaviour and address how the shortening may be beneficial to improve stability.

3D FE pushover and non-linear dynamic analyses of a masonry chimney before and after shortening

BERTOLESI, ELISA;MILANI, GABRIELE;
2015-01-01

Abstract

A masonry chimney 50 meters high, severely damaged by the May 2012 Emilia-Romagna (Italy) seismic sequence is numerically analyzed by means of non linear static and dynamic FE techniques. The state of damage on the upper part of the structure led to take the decision to shorten the chimney for security reasons, with a reduction of the height up to 37 meters. A modal pushover analysis (MPA) where force distributions based on the principal vibration modes is used to analyze the structure, finding for the 50 meters case crack patterns consistent with the observed ones. In addition, it is shown how, before and after shortening, the behavior factor to be used in modal response spectrum analyses, estimated directly from the MPA results, is slightly higher than unity, indicating a very low dissipative capacity. To validate static approach results, non-linear dynamic analyses are carried out using natural accelerograms and for the masonry material a damage-plasticity model. The residual deformations obtained and the crack patterns found exhibit convincing similarities with the real behaviour and address how the shortening may be beneficial to improve stability.
2015
COMPDYN 2015 - 5th ECCOMAS Thematic Conference on Computational Methods in Structural Dynamics and Earthquake Engineering
Masonry chimney; Nonlinear analysis; Pushover; Seismic-risk assessment; Vibration mode; Computers in Earth Sciences; Computational Mathematics; Geotechnical Engineering and Engineering Geology
File in questo prodotto:
File Dimensione Formato  
2015_COMPDYN.pdf

Accesso riservato

Descrizione: 2015_COMPDYN
: Publisher’s version
Dimensione 296.53 kB
Formato Adobe PDF
296.53 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/971853
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact