Outdoor test cells have been extensively used for analyzing the thermo-physical properties of building envelope components under real climate conditions. The paper presents a new test cell facility, under development at the Ecole Spéciale des Travaux Publics, du Bâtiment et de l'Industrie (ESTP Paris) within the framework of a collaboration between the end-use Efficiency Research Group of Politecnico di Milano and ESTP. The facility will allow to obtain reliable estimates of thermal performance indicators of transparent and opaque building elements. A particular care has been taken in the design phase in order to minimize or to accurately evaluate all sources of uncertainty, such as (i) conductive heat losses through the test cell envelope, (ii) time lag of response to transient solar conditions, (iii) levels of airtightness and of resistance to vapour or water penetration..

Conception of a new test cell facility for characterizing building envelope components

CATTARIN, GIULIO;CAUSONE, FRANCESCO;PAGLIANO, LORENZO
2015-01-01

Abstract

Outdoor test cells have been extensively used for analyzing the thermo-physical properties of building envelope components under real climate conditions. The paper presents a new test cell facility, under development at the Ecole Spéciale des Travaux Publics, du Bâtiment et de l'Industrie (ESTP Paris) within the framework of a collaboration between the end-use Efficiency Research Group of Politecnico di Milano and ESTP. The facility will allow to obtain reliable estimates of thermal performance indicators of transparent and opaque building elements. A particular care has been taken in the design phase in order to minimize or to accurately evaluate all sources of uncertainty, such as (i) conductive heat losses through the test cell envelope, (ii) time lag of response to transient solar conditions, (iii) levels of airtightness and of resistance to vapour or water penetration..
2015
Proceeding of: CIGOS2015 Conference
test cell, building envelope, experimental test, outdoor facility, guarded hot box
File in questo prodotto:
File Dimensione Formato  
The Box Office Paper CIGOS_GC_AK_LP_FC AM_.pdf

accesso aperto

Descrizione: full paper
: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 257.88 kB
Formato Adobe PDF
257.88 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/971645
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact