The behavior of single bricks and small masonry pillars strengthened by means of fabric reinforced cementitious matrix systems made with glass-fiber grids is discussed both from an experimental and numerical standpoint.A standard Push-pull double lap test is performed on three different series of experimental set-ups for reinforced single bricks and on masonry pillars, evaluating the role played by the anchorage length on the overall behavior of the strengthened system.Standard Italian bricks with very good mechanical properties are used, in order to evaluate the ultimate strength of the grid for delamination within the mortar. The masonry pillar is built with 3 bricks spaced out by two thick mortar joints. When dealing with the single bricks, three different anchorage lengths were tested, equal to 5, 10 and 15. cm, in order to evaluate the reduction of the ultimate strength induced by an insufficient anchorage.To suitably interpret experimental results, both a newly developed analytical-numerical approach and a recently presented 3D FEM model were utilized to have an insight into experimental results.In the analytical-numerical approach only the glass-fiber grid was considered and modeled by means of 1D Finite Elements interacting with the surrounding mortar by means of interfaces exhibiting a non-linear stress-slip behavior deduced from experimental data.The 3D model uses 8-noded rigid elements interconnected by inelastic interfaces exhibiting softening. The incremental non-linear problem is solved by means of a robust Sequential Quadratic Programming routine already tested on medium and large scale examples with softening materials. The grid is modeled through non-linear truss elements, interacting with surrounding mortar by means of non-linear interfacial tangential stresses. Stress-slip behavior of the interface between the mortar and the textile is deduced through ad hoc experimentation conducted on a mortar specimen reinforced with a single yarn and subjected to a standard tensile test.Good agreement was found between experimental evidences and numerical simulations, meaning that the combined approach proposed may be considered as reference for design considerations.

Mechanical properties and numerical modeling of Fabric Reinforced Cementitious Matrix (FRCM) systems for strengthening of masonry structures

CAROZZI, FRANCESCA GIULIA;MILANI, GABRIELE;POGGI, CARLO
2014-01-01

Abstract

The behavior of single bricks and small masonry pillars strengthened by means of fabric reinforced cementitious matrix systems made with glass-fiber grids is discussed both from an experimental and numerical standpoint.A standard Push-pull double lap test is performed on three different series of experimental set-ups for reinforced single bricks and on masonry pillars, evaluating the role played by the anchorage length on the overall behavior of the strengthened system.Standard Italian bricks with very good mechanical properties are used, in order to evaluate the ultimate strength of the grid for delamination within the mortar. The masonry pillar is built with 3 bricks spaced out by two thick mortar joints. When dealing with the single bricks, three different anchorage lengths were tested, equal to 5, 10 and 15. cm, in order to evaluate the reduction of the ultimate strength induced by an insufficient anchorage.To suitably interpret experimental results, both a newly developed analytical-numerical approach and a recently presented 3D FEM model were utilized to have an insight into experimental results.In the analytical-numerical approach only the glass-fiber grid was considered and modeled by means of 1D Finite Elements interacting with the surrounding mortar by means of interfaces exhibiting a non-linear stress-slip behavior deduced from experimental data.The 3D model uses 8-noded rigid elements interconnected by inelastic interfaces exhibiting softening. The incremental non-linear problem is solved by means of a robust Sequential Quadratic Programming routine already tested on medium and large scale examples with softening materials. The grid is modeled through non-linear truss elements, interacting with surrounding mortar by means of non-linear interfacial tangential stresses. Stress-slip behavior of the interface between the mortar and the textile is deduced through ad hoc experimentation conducted on a mortar specimen reinforced with a single yarn and subjected to a standard tensile test.Good agreement was found between experimental evidences and numerical simulations, meaning that the combined approach proposed may be considered as reference for design considerations.
2014
File in questo prodotto:
File Dimensione Formato  
2014_COST.pdf

Accesso riservato

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 3.93 MB
Formato Adobe PDF
3.93 MB Adobe PDF   Visualizza/Apri
Mechanical properties of FRCM_11311-765310_Poggi.pdf

accesso aperto

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 3.84 MB
Formato Adobe PDF
3.84 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/765310
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 171
  • ???jsp.display-item.citation.isi??? 141
social impact