Hardware-in-the-loop (HIL) simulation is a promising technique to study the pantograph-catenary interaction problems by realising the interaction of a physical pantograph with a mathematical model of the overhead equipment (catenary). However, the computing power presently available on real-time CPUs only allows to run simplified models of the overhead equipment. Therefore, it is important to define catenary models that are suitable for real-time simulation and at the same time capable of accurately representing the dynamic behaviour of the catenary. In this paper, the use of a catenary model based on modal superposition is considered, and the effect of changing the number of modelled spans and the number of modal components allocated to the contact and messenger wires is investigated in view of finding the best model compatible with real-time simulation. Comparisons between HIL simulation results and line measurements are presented, to quantify the accuracy of the hybrid simulation method developed.
Real-time catenary models for the hardware-in-the-loop simulation of the pantograph–catenary interaction
FACCHINETTI, ALAN;GASPARETTO, LIVIO;BRUNI, STEFANO
2013-01-01
Abstract
Hardware-in-the-loop (HIL) simulation is a promising technique to study the pantograph-catenary interaction problems by realising the interaction of a physical pantograph with a mathematical model of the overhead equipment (catenary). However, the computing power presently available on real-time CPUs only allows to run simplified models of the overhead equipment. Therefore, it is important to define catenary models that are suitable for real-time simulation and at the same time capable of accurately representing the dynamic behaviour of the catenary. In this paper, the use of a catenary model based on modal superposition is considered, and the effect of changing the number of modelled spans and the number of modal components allocated to the contact and messenger wires is investigated in view of finding the best model compatible with real-time simulation. Comparisons between HIL simulation results and line measurements are presented, to quantify the accuracy of the hybrid simulation method developed.File | Dimensione | Formato | |
---|---|---|---|
VSD_2013_vol51_4_pp499-516.pdf
Accesso riservato
:
Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione
583.76 kB
Formato
Adobe PDF
|
583.76 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.