This paper presents an automated real-time atrial fibrillation (AF) detection approach that relies on the observation of two characteristic irregularities of AF episodes in the electrocardiogram (ECG) signal. The results generated after the analysis of these irregularities are subsequently analyzed in real-time using a new fuzzy classifier. We have optimized this novel AF classification framework to require very limited processing, memory storage and energy resources, which makes it able to operate in real-time on a wearable wireless sensor platform. Moreover, our experimental results indicate that the proposed on-line approach shows a similar accuracy to state-of-the-art off-line AF detectors, achieving up to 96% sensitivity and 93% specificity. Finally, we present a detailed energy study of each component of the target wearable wireless sensor platform, while executing the automated AF detection approach in a real operating scenario, in order to evaluate the lifetime of the overall system. This study indicates that the lifetime of the platform is increased by using the proposed method to detect AF in real-time and diagnose the patient with respect to a streaming application that sends the raw signal to a central coordinator (e.g., smartphone or laptop) for its ulterior processing.

Automated real-time atrial fibrillation detection on a wearable wireless sensor platform

GRASSI, PAOLO ROBERTO;SCIUTO, DONATELLA
2012-01-01

Abstract

This paper presents an automated real-time atrial fibrillation (AF) detection approach that relies on the observation of two characteristic irregularities of AF episodes in the electrocardiogram (ECG) signal. The results generated after the analysis of these irregularities are subsequently analyzed in real-time using a new fuzzy classifier. We have optimized this novel AF classification framework to require very limited processing, memory storage and energy resources, which makes it able to operate in real-time on a wearable wireless sensor platform. Moreover, our experimental results indicate that the proposed on-line approach shows a similar accuracy to state-of-the-art off-line AF detectors, achieving up to 96% sensitivity and 93% specificity. Finally, we present a detailed energy study of each component of the target wearable wireless sensor platform, while executing the automated AF detection approach in a real operating scenario, in order to evaluate the lifetime of the overall system. This study indicates that the lifetime of the platform is increased by using the proposed method to detect AF in real-time and diagnose the patient with respect to a streaming application that sends the raw signal to a central coordinator (e.g., smartphone or laptop) for its ulterior processing.
2012
Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
978-1-4244-4119-8
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/740772
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 31
social impact