In this paper an active modal TMD control logic for the vibration suppression is presented. Starting from the traditional TMD theory, a closed loop formulation is proposed to calculate the active control force. The possibility to describe every mechanical systems or civil structures with a set of modal coordinates allows to act independently on each modal degree of freedom. The technique is compared with different solutions already present in literature, such as the IMSC and the PPF. Numerical simulations, based on a FEM linear model, are carried out to investigate the pro and con of each logic.
Vibration control of flexible structures with anActive Modal Tuned Mass Damper
CAZZULANI, GABRIELE;GHIELMETTI, CHRISTIAN;RESTA, FERRUCCIO;RIPAMONTI, FRANCESCO
2011-01-01
Abstract
In this paper an active modal TMD control logic for the vibration suppression is presented. Starting from the traditional TMD theory, a closed loop formulation is proposed to calculate the active control force. The possibility to describe every mechanical systems or civil structures with a set of modal coordinates allows to act independently on each modal degree of freedom. The technique is compared with different solutions already present in literature, such as the IMSC and the PPF. Numerical simulations, based on a FEM linear model, are carried out to investigate the pro and con of each logic.File in questo prodotto: