Some converter configurations for wind energy systems are proposed. The conversion structures include capacitor loaded diode bridges directly feeding a grid side inverter. Because of the great variation of the PM generator voltage, due to the wide speed range, a winding commutation is adopted between parallel and series connection, at low speeds. Various features are analyzed, concerning converter sizing and operation aspects. Comparative remarks are made among the different conversion solutions.
Operation And Sizing Aspects of Converters for Wind Energy Systems Equipped with Direct-Drive, Permanent Magnet Generators
DI GERLANDO, ANTONINO;FOGLIA, GIOVANNI MARIA;PERINI, ROBERTO;UBALDINI, MARIO GIUSEPPE
2008-01-01
Abstract
Some converter configurations for wind energy systems are proposed. The conversion structures include capacitor loaded diode bridges directly feeding a grid side inverter. Because of the great variation of the PM generator voltage, due to the wide speed range, a winding commutation is adopted between parallel and series connection, at low speeds. Various features are analyzed, concerning converter sizing and operation aspects. Comparative remarks are made among the different conversion solutions.File in questo prodotto: