Efficiency in removing middle molecules such as ß2-microglobulin (ß2-MG) is one of the main purposes of modern dialytic therapy. In order to achieve this, techniques requiring complex machines and substitution fluid have been developed over recent years. Alternatively, the internal filtration / back filtration phenomenon can be used. The recent development of a so-called “internal filtration enhanced dialyser” prompted us to compare the removal of ß2-MG together with other small molecules when the dialyser was used either in standard hemodiafiltration (HDF) or internal hemodiafiltration (iHDF). Ten stable, anuric, hemodialysis (HD) patients treated by thrice weekly standard bicarbonate HD using low-flux synthetic membrane entered the study. A new high-flux polysulfone dialyser designed with the specific aim of enhancing internal filtration (BS-1.6 UL, 1.6 m2, Toray Industries) was used. Post dilution HDF (2.5 l/hour of substitution fluid, dialysate flow 500 ml/min) was compared with iHDF (dialysate flow 750 ml/min), with blood flow at 300 ml/min. Samples were obtained at the start and at the end of the session in order to measure the % removal of urea, creatinine, uric acid, phosphate and ß2-MG (corrected for total protein concentration). In addition, after 20 min of dialysis the clearances of the same molecules were measured. A mathematical model has been developed for the description of the hydrodynamic phenomena taking place within the dialyser and of fluid filtration across the membrane.

Clinical evaluation of internal hemodiafiltration (iHDF): A diffusive-convective technique performed with internal filtration enhanced high-flux dialyzers.

FIORE, GIANFRANCO BENIAMINO;GUADAGNI, GUALTIERO;FUMERO, ROBERTO;
2004-01-01

Abstract

Efficiency in removing middle molecules such as ß2-microglobulin (ß2-MG) is one of the main purposes of modern dialytic therapy. In order to achieve this, techniques requiring complex machines and substitution fluid have been developed over recent years. Alternatively, the internal filtration / back filtration phenomenon can be used. The recent development of a so-called “internal filtration enhanced dialyser” prompted us to compare the removal of ß2-MG together with other small molecules when the dialyser was used either in standard hemodiafiltration (HDF) or internal hemodiafiltration (iHDF). Ten stable, anuric, hemodialysis (HD) patients treated by thrice weekly standard bicarbonate HD using low-flux synthetic membrane entered the study. A new high-flux polysulfone dialyser designed with the specific aim of enhancing internal filtration (BS-1.6 UL, 1.6 m2, Toray Industries) was used. Post dilution HDF (2.5 l/hour of substitution fluid, dialysate flow 500 ml/min) was compared with iHDF (dialysate flow 750 ml/min), with blood flow at 300 ml/min. Samples were obtained at the start and at the end of the session in order to measure the % removal of urea, creatinine, uric acid, phosphate and ß2-MG (corrected for total protein concentration). In addition, after 20 min of dialysis the clearances of the same molecules were measured. A mathematical model has been developed for the description of the hydrodynamic phenomena taking place within the dialyser and of fluid filtration across the membrane.
2004
Hemodiafiltration
File in questo prodotto:
File Dimensione Formato  
IJAO-Hemodiafiltration.pdf

Accesso riservato

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 68.59 kB
Formato Adobe PDF
68.59 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/239745
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 23
social impact