The transition to a low-carbon energy system necessitates the development of large-scale hydrogen storage solutions. Lined rock caverns (LRCs), which have demonstrated effectiveness for natural gas storage in Sweden and South Korea, present significant potential for hydrogen storage by integrating steel-concrete liner integrity with rock mass stability. Nevertheless, the unique physical and chemical properties of hydrogen (including its smaller molecular size, higher diffusivity, susceptibility to material embrittlement, and markedly different thermodynamic behaviour) pose challenges that are not present in conventional gas storage. This study systematically identifies critical knowledge gaps in hydrogen LRC design through a comparative analysis of storage requirements for natural gas and hydrogen. A comprehensive thermal analysis framework, developed through three methodological approaches, demonstrates that accurate prediction of thermal behaviour necessitates the use of real gas state equations. Preliminary analysis employing the Peng-Robinson equation with iterative thermo-hydraulic coupling indicates that a 10-day charging period to 30 MPa results in peak temperatures of 96°C and compressibility factors reaching Z=1.116, which substantially exceed ideal gas predictions (87°C, Z = 1.0). The 10.7% underestimation of temperature by ideal gas theory may result in surpassing concrete temperature limits, while the corresponding 21.7% overestimation of storage capacity could adversely affect project economics. Thermal stresses in the concrete ring (26.3 MPa) are comparable to mechanical stresses from internal pressure, underscoring the necessity of accounting for thermal effects in structural design. A multi-scenario analysis of charging durations (10–30 days) quantifies key trade-offs: extending the charging period from 10 to 30 days reduces peak temperature by 22% (from 96°C to 74°C) but decreases annual throughput by 66% (from 23,792 to 8,089 tonnes per year). This study establishes a framework for multi-physics coupled analysis, identifies essential limit states and performance criteria specific to hydrogen storage, and provides a foundation for developing reliable design methodologies required for the safe deployment of hydrogen LRCs.

Framing the Challenge: Towards Reliable Structural Solutions for Lined Rock Caverns for Hydrogen Storage

Aida Sabbaghian Toosi;Gabriele Della Vecchia;Giovanni Muciaccia;Liberato Ferrara
2026-01-01

Abstract

The transition to a low-carbon energy system necessitates the development of large-scale hydrogen storage solutions. Lined rock caverns (LRCs), which have demonstrated effectiveness for natural gas storage in Sweden and South Korea, present significant potential for hydrogen storage by integrating steel-concrete liner integrity with rock mass stability. Nevertheless, the unique physical and chemical properties of hydrogen (including its smaller molecular size, higher diffusivity, susceptibility to material embrittlement, and markedly different thermodynamic behaviour) pose challenges that are not present in conventional gas storage. This study systematically identifies critical knowledge gaps in hydrogen LRC design through a comparative analysis of storage requirements for natural gas and hydrogen. A comprehensive thermal analysis framework, developed through three methodological approaches, demonstrates that accurate prediction of thermal behaviour necessitates the use of real gas state equations. Preliminary analysis employing the Peng-Robinson equation with iterative thermo-hydraulic coupling indicates that a 10-day charging period to 30 MPa results in peak temperatures of 96°C and compressibility factors reaching Z=1.116, which substantially exceed ideal gas predictions (87°C, Z = 1.0). The 10.7% underestimation of temperature by ideal gas theory may result in surpassing concrete temperature limits, while the corresponding 21.7% overestimation of storage capacity could adversely affect project economics. Thermal stresses in the concrete ring (26.3 MPa) are comparable to mechanical stresses from internal pressure, underscoring the necessity of accounting for thermal effects in structural design. A multi-scenario analysis of charging durations (10–30 days) quantifies key trade-offs: extending the charging period from 10 to 30 days reduces peak temperature by 22% (from 96°C to 74°C) but decreases annual throughput by 66% (from 23,792 to 8,089 tonnes per year). This study establishes a framework for multi-physics coupled analysis, identifies essential limit states and performance criteria specific to hydrogen storage, and provides a foundation for developing reliable design methodologies required for the safe deployment of hydrogen LRCs.
2026
Structural Concrete 2050: Towards Carbon Neutrality, AI Design, and Robotic Construction – Proceedings of the 7th fib Congress
hydrogen storage, lined rock caverns, structural stability, Peng-Robinson equation of state, thermal analysis, multi-physics coupling
File in questo prodotto:
File Dimensione Formato  
fib-proceedings-2026.pdf

Accesso riservato

: Publisher’s version
Dimensione 908.47 kB
Formato Adobe PDF
908.47 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1333125
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact