Monitoring the prompt gamma rays emitted by the patient during irradiation enables potentially real-time verification of the treatment, particularly for detecting range shifts that may arise from patient motion and other sources of uncertainties. Keeping the detector inside the treatment room throughout irradiation would therefore provide valuable information without interrupting the clinical workflow. The integration of such a detector requires a dedicated positioning system. This work presents a novel detector positioning system designed for clinical use. The system consists of a trolley attached to the couch via the lockbar engagement and equipped with four legs that transfer the system's weight to the floor. Experiments were carried out at CNAO (Pavia). This center has a fixed beamline, then requiring the couch to move across multiple fields with a pantograph, the Patient Positioning System (PPS). To avoid interference with the PPS, the legs should be retracted during couch movements and lowered once the treatment position is reached. The elastic behavior of the couch under these conditions was experimentally characterized, confirming that leg retraction does not introduce measurable deformation. To further minimize treatment time, the detector is intended to remain inside the room even during the acquisition of diagnostic X-ray images. Interference analyses were therefore performed to determine the geometric conditions under which this is feasible, resulting in operational limits that allow the system to remain in place from patient setup through irradiation.
Towards a novel positioning system for a real-time prompt gamma imaging detector in hadrontherapy
L. Santini;K. Urban;A. Forgione;M. Piroddi;C. Riboldi;G. Baroni;G. Borghi;M. Carminati;C. Fiorini
2026-01-01
Abstract
Monitoring the prompt gamma rays emitted by the patient during irradiation enables potentially real-time verification of the treatment, particularly for detecting range shifts that may arise from patient motion and other sources of uncertainties. Keeping the detector inside the treatment room throughout irradiation would therefore provide valuable information without interrupting the clinical workflow. The integration of such a detector requires a dedicated positioning system. This work presents a novel detector positioning system designed for clinical use. The system consists of a trolley attached to the couch via the lockbar engagement and equipped with four legs that transfer the system's weight to the floor. Experiments were carried out at CNAO (Pavia). This center has a fixed beamline, then requiring the couch to move across multiple fields with a pantograph, the Patient Positioning System (PPS). To avoid interference with the PPS, the legs should be retracted during couch movements and lowered once the treatment position is reached. The elastic behavior of the couch under these conditions was experimentally characterized, confirming that leg retraction does not introduce measurable deformation. To further minimize treatment time, the detector is intended to remain inside the room even during the acquisition of diagnostic X-ray images. Interference analyses were therefore performed to determine the geometric conditions under which this is feasible, resulting in operational limits that allow the system to remain in place from patient setup through irradiation.| File | Dimensione | Formato | |
|---|---|---|---|
|
Santini_2026_J._Inst._21_T08010-2.pdf
accesso aperto
Dimensione
8.23 MB
Formato
Adobe PDF
|
8.23 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.