Sterile neutrinos are a minimal extension of the Standard Model of particle physics and a promising candidate for dark matter if their mass is in the keV-range. The Karlsruhe Tritium Neutrino experiment (KATRIN), equipped with a novel multi-pixel silicon drift detector array, the TRISTAN detector, will be capable of searching for these keV-scale sterile neutrinos by investigating the kinematics of the tritium β-decay. This measurement will be performed after the completion of the neutrino mass measurement campaign. To detect a sterile neutrino signal with a high sensitivity, a profound understanding of the detector response is required. In this work, we report on the characterization of a 7-pixel TRISTAN prototype detector with a laser system. We present the experimental results obtained in high-resolution scans of the detector surface with a focused laser beam and demonstrate how the charge collection and the timing of the signals generated in the detector is related to the detector geometry. A comparison of the experimental data with simulations shows a good agreement.

Investigations of charge collection and signal timing in a multi-pixel silicon drift detector

Urban, K.;Carminati, M.;Fiorini, C.;
2025-01-01

Abstract

Sterile neutrinos are a minimal extension of the Standard Model of particle physics and a promising candidate for dark matter if their mass is in the keV-range. The Karlsruhe Tritium Neutrino experiment (KATRIN), equipped with a novel multi-pixel silicon drift detector array, the TRISTAN detector, will be capable of searching for these keV-scale sterile neutrinos by investigating the kinematics of the tritium β-decay. This measurement will be performed after the completion of the neutrino mass measurement campaign. To detect a sterile neutrino signal with a high sensitivity, a profound understanding of the detector response is required. In this work, we report on the characterization of a 7-pixel TRISTAN prototype detector with a laser system. We present the experimental results obtained in high-resolution scans of the detector surface with a focused laser beam and demonstrate how the charge collection and the timing of the signals generated in the detector is related to the detector geometry. A comparison of the experimental data with simulations shows a good agreement.
2025
Detector alignment and calibration methods (lasers, sources, particle-beams)
Detector modelling and simulations II (electric fields, charge transport, multiplication and induction, pulse formation, electron emission, etc)
Interaction of radiation with matter
Solid state detectors
File in questo prodotto:
File Dimensione Formato  
Forstner_2025_J._Inst._20_P06013.pdf

Accesso riservato

: Publisher’s version
Dimensione 7.43 MB
Formato Adobe PDF
7.43 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1308905
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact