Aims: Bicuspid aortic valve (BAV) represents a challenge for transcatheter aortic valve implantation (TAVI). Few data are reported about the procedural implications of BAV using different self-expandable devices. The aim of this study is to investigate how BAV and tricuspid aortic valve (TAV) morphologies influence device selection and their impact on the potential development of post-operative conduction disturbances, using a novel in silico approach. Methods and results: Five patients with BAV undergoing TAVI were enrolled. TAVs were virtually modelled within each BAV patient-specific anatomy, resulting in 10 virtual patients. Acurate Neo2 and Evolut R implantations were subsequently simulated across all cases. Post-implantation stresses exerted on both the stent and aortic root were measured, allowing a comparative analysis of the impact of the two valve morphologies. Comparing stent stresses between BAV and TAV configurations, the stress gap increased by 21.96 ± 5.35% (P = 0.01) in Acurate Neo2 cases (n = 6) compared with Evolut R cases (n = 4). The analysis of aortic root stresses showed no significant differences between BAV (n = 5) and TAV (n = 5) configurations, with a mean stress difference of 5.1 ± 8.17% (P > 0.05). Conclusion: Our patient-specific model shows that high radial force devices, such as Evolut R, demonstrate consistent expansion regardless of valve morphology, without increasing the risk of post-implantation conduction disturbances, hence resulting more suitable for BAV cases. Incorporating this methodology into pre-operative planning could support clinicians in selecting the most suitable device with a patient-specific approach.

The impact of bicuspid valve morphology on the selection of transcatheter aortic valve implantation devices: an in silico study

Grossi, Benedetta;Luraghi, Giulia;Barati, Sara;Migliavacca, Francesco;
2025-01-01

Abstract

Aims: Bicuspid aortic valve (BAV) represents a challenge for transcatheter aortic valve implantation (TAVI). Few data are reported about the procedural implications of BAV using different self-expandable devices. The aim of this study is to investigate how BAV and tricuspid aortic valve (TAV) morphologies influence device selection and their impact on the potential development of post-operative conduction disturbances, using a novel in silico approach. Methods and results: Five patients with BAV undergoing TAVI were enrolled. TAVs were virtually modelled within each BAV patient-specific anatomy, resulting in 10 virtual patients. Acurate Neo2 and Evolut R implantations were subsequently simulated across all cases. Post-implantation stresses exerted on both the stent and aortic root were measured, allowing a comparative analysis of the impact of the two valve morphologies. Comparing stent stresses between BAV and TAV configurations, the stress gap increased by 21.96 ± 5.35% (P = 0.01) in Acurate Neo2 cases (n = 6) compared with Evolut R cases (n = 4). The analysis of aortic root stresses showed no significant differences between BAV (n = 5) and TAV (n = 5) configurations, with a mean stress difference of 5.1 ± 8.17% (P > 0.05). Conclusion: Our patient-specific model shows that high radial force devices, such as Evolut R, demonstrate consistent expansion regardless of valve morphology, without increasing the risk of post-implantation conduction disturbances, hence resulting more suitable for BAV cases. Incorporating this methodology into pre-operative planning could support clinicians in selecting the most suitable device with a patient-specific approach.
2025
TAVI
bicuspid aortic valve
finite element method
patient-specific simulations
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1300369
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact