As deploying large amounts of monitoring equipment results in elevated cost and power consumption, novel low-cost monitoring methods are being continuously investigated. A new technique called Power Profile Monitoring (PPM) has recently gained traction thanks to its ability to monitor an entire lightpath using a single post-processing unit at the lightpath receiver. PPM does not require to deploy an individual monitor for each span, as in the traditional monitoring technique using Optical Time-Domain Reflectometer (OTDR). In this work, we aim to quantify the cost and power consumption of PPM (using OTDR as a baseline reference), as this analysis can provide guidelines for the implementation and deployment of PPM. First, we discuss how PPM and OTDR monitors are deployed, and we formally state a new Optimized Monitoring Placement (OMP) problem for PPM. Solving the OMP problem allows to identify the minimum number of PPM monitors that guarantees that all links in the networks are monitored by at least n PPM monitors (note that using n>1 allows for increased monitoring accuracy). We prove the NP-hardness of the OMP problem and formulate it using an Integer Linear Programming (ILP) model. Finally, we also devise a heuristic algorithm for the OMP problem to scale to larger topologies. Our numerical results, obtained on realistic topologies, suggest that the cost (and power) of one PPM module should be lower than 2.6 times that of one OTDR for nation-wide and 10.2 times for continental-wide topology.

Cost and power-consumption analysis for power profile monitoring with multiple monitors per link in optical networks

Zhang, Qiaolun;Attarpour, Aryanaz;Tornatore, Massimo
2025-01-01

Abstract

As deploying large amounts of monitoring equipment results in elevated cost and power consumption, novel low-cost monitoring methods are being continuously investigated. A new technique called Power Profile Monitoring (PPM) has recently gained traction thanks to its ability to monitor an entire lightpath using a single post-processing unit at the lightpath receiver. PPM does not require to deploy an individual monitor for each span, as in the traditional monitoring technique using Optical Time-Domain Reflectometer (OTDR). In this work, we aim to quantify the cost and power consumption of PPM (using OTDR as a baseline reference), as this analysis can provide guidelines for the implementation and deployment of PPM. First, we discuss how PPM and OTDR monitors are deployed, and we formally state a new Optimized Monitoring Placement (OMP) problem for PPM. Solving the OMP problem allows to identify the minimum number of PPM monitors that guarantees that all links in the networks are monitored by at least n PPM monitors (note that using n>1 allows for increased monitoring accuracy). We prove the NP-hardness of the OMP problem and formulate it using an Integer Linear Programming (ILP) model. Finally, we also devise a heuristic algorithm for the OMP problem to scale to larger topologies. Our numerical results, obtained on realistic topologies, suggest that the cost (and power) of one PPM module should be lower than 2.6 times that of one OTDR for nation-wide and 10.2 times for continental-wide topology.
2025
File in questo prodotto:
File Dimensione Formato  
OSN_PPM.pdf

accesso aperto

: Pre-Print (o Pre-Refereeing)
Dimensione 711.9 kB
Formato Adobe PDF
711.9 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1298745
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact