(1) Background: Upper limb (UL) function plays a central role in daily life, enabling essen- tial tasks such as reaching, grasping, and eating. While numerous tools exist to evaluate UL kinematics, their application in pediatric populations is often limited by a lack of age-specific validation. This study presents a novel motion analysis protocol featuring a customized marker set, aimed at assessing UL movements in the three anatomical planes across different age groups, with a focus on pediatric applicability. (2) Materials and Meth- ods: A SmartDX motion capture system was used, with 30 markers positioned on the upper body, referencing the trunk as the root of the kinematic chain. Ten healthy participants (mean age: 18.69 ± 12.45 years; range: 8.0–41.4) without UL impairments were recruited. The broad age range was intentionally selected to assess the protocol’s transversal appli- cability. (3) Results: Results showed excellent intra-operator reliability for shoulder and wrist kinematics (ICC > 0.906) and good reliability for elbow movements (ICC > 0.755). Inter-operator reliability was good to excellent (shoulder ICC > 0.958; elbow ICC > 0.762; wrist ICC > 0.826) Usability, measured via the System Usability Scale, was rated as good (83.25). (4) Conclusions: The proposed protocol demonstrated strong reliability and prac- tical usability, supporting its adoption in clinical and research settings. Its design allows for adaptability across motion capture platforms, promoting wider implementation in pediatric UL functional assessment.

A Novel Protocol for Integrated Assessment of Upper Limbs Using the Optoelectronic Motion Analysis System: Validation and Usability in Healthy People

Andreoni, Giuseppe
2025-01-01

Abstract

(1) Background: Upper limb (UL) function plays a central role in daily life, enabling essen- tial tasks such as reaching, grasping, and eating. While numerous tools exist to evaluate UL kinematics, their application in pediatric populations is often limited by a lack of age-specific validation. This study presents a novel motion analysis protocol featuring a customized marker set, aimed at assessing UL movements in the three anatomical planes across different age groups, with a focus on pediatric applicability. (2) Materials and Meth- ods: A SmartDX motion capture system was used, with 30 markers positioned on the upper body, referencing the trunk as the root of the kinematic chain. Ten healthy participants (mean age: 18.69 ± 12.45 years; range: 8.0–41.4) without UL impairments were recruited. The broad age range was intentionally selected to assess the protocol’s transversal appli- cability. (3) Results: Results showed excellent intra-operator reliability for shoulder and wrist kinematics (ICC > 0.906) and good reliability for elbow movements (ICC > 0.755). Inter-operator reliability was good to excellent (shoulder ICC > 0.958; elbow ICC > 0.762; wrist ICC > 0.826) Usability, measured via the System Usability Scale, was rated as good (83.25). (4) Conclusions: The proposed protocol demonstrated strong reliability and prac- tical usability, supporting its adoption in clinical and research settings. Its design allows for adaptability across motion capture platforms, promoting wider implementation in pediatric UL functional assessment.
2025
upper limb; functional assessment; kinematic analysis; shoulder kinematics; elbow kinematics; wrist kinematics
File in questo prodotto:
File Dimensione Formato  
bioengineering-12-00905-v2.pdf

accesso aperto

: Publisher’s version
Dimensione 2.46 MB
Formato Adobe PDF
2.46 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1295474
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact