CISPR 11 and CISPR 32 define the radiated emission tests to be conducted in a semi-anechoic chamber equipped with controllable turntable and antenna mast, leading to an expensive and time-consuming test procedure. By noting the fact that table-top test setup usually involves long interconnecting cable bundle that radiates significantly, the work proposes a fast and simple pre-compliance radiated emission evaluation method based on cascaded Hertzian dipoles and its radiation theory. Several factors in the CISPR 11/32 test setups are integrated into this evaluation method to mimic a real test procedure. The accuracy of the proposed method is validated by an experimental test. A systematic analysis of the accuracy and applicability of the proposed method is also provided, showing that the method presents a simple, reliable and easy-to-be-implemented prediction tool for early-stage pre-compliance radiation evaluation, according to CISPR 11/32 testing.
A Simple Cable Radiated Emission Evaluation Method for Table-Top Setups According to CISPR 11 and CISPR 32
Wu X.;Grande A.;Liu X.;Grassi F.;Spadacini G.;Pignari S. A.;
2025-01-01
Abstract
CISPR 11 and CISPR 32 define the radiated emission tests to be conducted in a semi-anechoic chamber equipped with controllable turntable and antenna mast, leading to an expensive and time-consuming test procedure. By noting the fact that table-top test setup usually involves long interconnecting cable bundle that radiates significantly, the work proposes a fast and simple pre-compliance radiated emission evaluation method based on cascaded Hertzian dipoles and its radiation theory. Several factors in the CISPR 11/32 test setups are integrated into this evaluation method to mimic a real test procedure. The accuracy of the proposed method is validated by an experimental test. A systematic analysis of the accuracy and applicability of the proposed method is also provided, showing that the method presents a simple, reliable and easy-to-be-implemented prediction tool for early-stage pre-compliance radiation evaluation, according to CISPR 11/32 testing.File | Dimensione | Formato | |
---|---|---|---|
IEEE_A_Simple_Cable_Radiated_Emission_Evaluation_Method_for_Table-Top_Setups_According_to_CISPR_11_and_CISPR_32.pdf
accesso aperto
Descrizione: Articolo principale
:
Publisher’s version
Dimensione
3.05 MB
Formato
Adobe PDF
|
3.05 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.