This paper presents a novel multi-channel portable bioelectronic platform for multiplex detection, i.e. for reading a biosensor chip with multiple sensing sites for real-time multi target capturing. The system is based on Differential Impedance Sensing (DIS) of specific biomolecules with nanoparticle amplification. The sensor surface houses 7 sites of gold-interdigitated microelectrodes designed in a differential configuration, reference and sensing, to counteract temperature fluctuations and variations in the ion content of the solution. The multichannel electronic platform has been validated by selectively detecting a target DNA oligonucleotide only on 3 specific sensor sites, leaving 2 negative controls and 2 reference sites clean. The system allows for easy and effective bio-reconfigurability, leveraging the advances in molecular recognition by properly selecting bio-probes for each sensing site, extending the applicability of Multiplex detection to a vast range of diagnostic approaches.
Bio-Reconfigurable Differential Impedance Electronic Platform for Multiplex Biomarker Detection
Piedimonte, Paola;Zanetto, Francesco;Maurina, Arianna Adelaide;Ferrari, Giorgio;de Oliveira Figares, Cainã;Sampietro, Marco
2023-01-01
Abstract
This paper presents a novel multi-channel portable bioelectronic platform for multiplex detection, i.e. for reading a biosensor chip with multiple sensing sites for real-time multi target capturing. The system is based on Differential Impedance Sensing (DIS) of specific biomolecules with nanoparticle amplification. The sensor surface houses 7 sites of gold-interdigitated microelectrodes designed in a differential configuration, reference and sensing, to counteract temperature fluctuations and variations in the ion content of the solution. The multichannel electronic platform has been validated by selectively detecting a target DNA oligonucleotide only on 3 specific sensor sites, leaving 2 negative controls and 2 reference sites clean. The system allows for easy and effective bio-reconfigurability, leveraging the advances in molecular recognition by properly selecting bio-probes for each sensing site, extending the applicability of Multiplex detection to a vast range of diagnostic approaches.File | Dimensione | Formato | |
---|---|---|---|
Bio-Reconfigurable_Differential_Impedance_Electronic_Platform_for_Multiplex_Biomarker_Detection.pdf
embargo fino al 18/01/2025
Descrizione: Articolo
:
Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione
522.01 kB
Formato
Adobe PDF
|
522.01 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.