We present a loosely coupled scheme for the numerical simulation of the cardiac electro-fluid-structure interaction problem, whose solution is typically computationally intensive due to the need to suitably treat the coupling of the different submodels. Our scheme relies on a segregated treatment of the subproblems, in particular on an explicit Robin-Neumann algorithm for the fluid-structure interaction, aiming at reducing the computational burden of numerical simulations. The results, both in an ideal and a realistic cardiac setting, show that the proposed scheme is stable at the regimes typical of cardiac simulations. From a comparison with a scheme with implicit fluid-structure interaction, it emerges that, while conservation properties are not fully preserved, computational times significantly benefit from the explicit scheme. Overall, the explicit discretization represents a good trade-off between accuracy and cost, and is a valuable alternative to implicit schemes for fast large-scale simulations.
A stable loosely-coupled scheme for cardiac electro-fluid-structure interaction
Bucelli M.;Quarteroni A.;Vergara C.
2023-01-01
Abstract
We present a loosely coupled scheme for the numerical simulation of the cardiac electro-fluid-structure interaction problem, whose solution is typically computationally intensive due to the need to suitably treat the coupling of the different submodels. Our scheme relies on a segregated treatment of the subproblems, in particular on an explicit Robin-Neumann algorithm for the fluid-structure interaction, aiming at reducing the computational burden of numerical simulations. The results, both in an ideal and a realistic cardiac setting, show that the proposed scheme is stable at the regimes typical of cardiac simulations. From a comparison with a scheme with implicit fluid-structure interaction, it emerges that, while conservation properties are not fully preserved, computational times significantly benefit from the explicit scheme. Overall, the explicit discretization represents a good trade-off between accuracy and cost, and is a valuable alternative to implicit schemes for fast large-scale simulations.File | Dimensione | Formato | |
---|---|---|---|
EFSI-loosely-coupled-JCP-2023.pdf
accesso aperto
Descrizione: articolo pubblicato
:
Publisher’s version
Dimensione
2.78 MB
Formato
Adobe PDF
|
2.78 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.