This paper presents the results of an experimental program involving shake table testing of two full-scale reinforced concrete frame buildings. These tests were conducted to investigate the effectiveness and reliability of a newly proposed servo-hydraulic Active Mass Damper (AMD) that can be designed to enhance the target seismic performance of a building at multiple earthquake intensity levels. The two nominally identical case-study buildings were intentionally designed to exhibit a "soft story" mechanism at the first level when subject to ground shaking of sufficient intensity, but one was equipped with the newly proposed AMD, installed on the roof. The two specimens were then subject to the same loading protocol consisting of a ground shaking sequence of varying intensity, with the seismic input consisting of a selected natural ground motion.The experimental results demonstrated that the proposed AMD is extremely effective at enhancing building seismic performance. Specifically, the AMD provided peak displacement reductions in the order of 70% and was shown capable of absorbing more than 60% of the total input energy. As a consequence, the un-retrofitted structure suffered nontrivial structural and non-structural damage, while the AMD-retrofitted building remained virtually undamaged at all shaking intensities considered.

Full-Scale Shake Table Tests of a Reinforced Concrete Building Equipped with a Novel Servo-Hydraulic Active Mass Damper

Ripamonti, F;
2022-01-01

Abstract

This paper presents the results of an experimental program involving shake table testing of two full-scale reinforced concrete frame buildings. These tests were conducted to investigate the effectiveness and reliability of a newly proposed servo-hydraulic Active Mass Damper (AMD) that can be designed to enhance the target seismic performance of a building at multiple earthquake intensity levels. The two nominally identical case-study buildings were intentionally designed to exhibit a "soft story" mechanism at the first level when subject to ground shaking of sufficient intensity, but one was equipped with the newly proposed AMD, installed on the roof. The two specimens were then subject to the same loading protocol consisting of a ground shaking sequence of varying intensity, with the seismic input consisting of a selected natural ground motion.The experimental results demonstrated that the proposed AMD is extremely effective at enhancing building seismic performance. Specifically, the AMD provided peak displacement reductions in the order of 70% and was shown capable of absorbing more than 60% of the total input energy. As a consequence, the un-retrofitted structure suffered nontrivial structural and non-structural damage, while the AMD-retrofitted building remained virtually undamaged at all shaking intensities considered.
2022
Active mass damper
full-scale shake table
reinforced-concrete buildings
enhancing seismic performance
tuned-mass damper
File in questo prodotto:
File Dimensione Formato  
220204_R&D_PP_Active-Mass-Damper-for-Seismic-Protection-of-Structures.pdf

Open Access dal 20/09/2023

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 1.83 MB
Formato Adobe PDF
1.83 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1227488
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact