The mechanical characterization of a 4 × 4 air-coupled array of Piezoelectric Micromachined Ultrasonic Transducers (PMUTs) is presented. The experimental campaign consists of three set of experimental tests, namely: topography measurements, small signal dynamic measurements, and vibrometry in the non-linear dynamic regime. The behavior of three different kinds of PMUT are reported. They differ according to the thermo-electrical treatment that has been applied to the piezoelectric material. The presence of the fabrication induced residual stresses is investigated and the treatment effect is evaluated in terms of the initial deflected configuration. The results reported in this paper represent an experimental mechanical investigation useful for the design of PMUT structures with advanced functionalities in the linear and non-linear regime.

Air-coupled PMUTs array with residual stresses: experimental tests in the linear and non-linear dynamic regime

Massimino G.;Lazarova B.;Quaglia F.;Corigliano A.
2020-01-01

Abstract

The mechanical characterization of a 4 × 4 air-coupled array of Piezoelectric Micromachined Ultrasonic Transducers (PMUTs) is presented. The experimental campaign consists of three set of experimental tests, namely: topography measurements, small signal dynamic measurements, and vibrometry in the non-linear dynamic regime. The behavior of three different kinds of PMUT are reported. They differ according to the thermo-electrical treatment that has been applied to the piezoelectric material. The presence of the fabrication induced residual stresses is investigated and the treatment effect is evaluated in terms of the initial deflected configuration. The results reported in this paper represent an experimental mechanical investigation useful for the design of PMUT structures with advanced functionalities in the linear and non-linear regime.
2020
acoustic-structure interaction
array
experimental characterization
non-linear dynamics
Piezoelectric Micromachined Ultrasonic Transducers (PMUTs)
ultrasound
File in questo prodotto:
File Dimensione Formato  
Air coupled PMUTs array with residual stresses experimental tests in the linear and non linear dynamic regime.pdf

accesso aperto

: Publisher’s version
Dimensione 6.17 MB
Formato Adobe PDF
6.17 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1171209
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact