This paper presents an experimental system with hardware-in-the-loop emulation of both a diesel engine and wind turbine prime movers. System equations are analysed to model the required dynamics of the prime movers and design the control of the emulators. Experimental and simulation results show the dynamic response of the emulated systems.
Emulation of prime movers in wind turbine and diesel generator systems for laboratory use
Iacchetti M.;
2019-01-01
Abstract
This paper presents an experimental system with hardware-in-the-loop emulation of both a diesel engine and wind turbine prime movers. System equations are analysed to model the required dynamics of the prime movers and design the control of the emulators. Experimental and simulation results show the dynamic response of the emulated systems.File in questo prodotto: