Externally bonded (EB) fiber reinforced polymer (FRP) composites have been effectively employed to strengthen existing reinforced concrete (RC) structures. However, relatively limited information is available regarding the long-term behavior of FRP-concrete joints. In this paper, different experimental tests are employed to investigate the effect of hygrothermal ageing on the bond behavior of a carbon FRP composite applied to a concrete substrate and on the mechanical properties of the epoxy resin and FRP composite considered. The experimental campaign includes tensile tests of epoxy resin, carbon FRP (CFRP) coupon, pull-off tests of the CFRP bonded to the concrete substrate, and single-lap direct-shear tests of CFRP-concrete joints. Specimens were conditioned in warm water (38 ± 2 °C) for 500, 1000, and 1500 h to accelerate the possible degradation induced by a simulated high-moisture exposure environment. The parameters studied were the tensile properties of epoxy resin and CFRP coupons and the fracture energy of the CFRP-concrete interface, which was computed from the CFRP strain measured in the single-lap direct-shear tests using the digital image correlation (DIC) method. Results indicate that both the mechanical properties of the epoxy resin and the CFRP-concrete interface fracture energy were slightly affected by the exposure conditions.

Influence of hygrothermal ageing on the mechanical properties of CFRP-concrete joints and of their components

Al-Lami K.;Colombi P.;D'Antino T.
2020-01-01

Abstract

Externally bonded (EB) fiber reinforced polymer (FRP) composites have been effectively employed to strengthen existing reinforced concrete (RC) structures. However, relatively limited information is available regarding the long-term behavior of FRP-concrete joints. In this paper, different experimental tests are employed to investigate the effect of hygrothermal ageing on the bond behavior of a carbon FRP composite applied to a concrete substrate and on the mechanical properties of the epoxy resin and FRP composite considered. The experimental campaign includes tensile tests of epoxy resin, carbon FRP (CFRP) coupon, pull-off tests of the CFRP bonded to the concrete substrate, and single-lap direct-shear tests of CFRP-concrete joints. Specimens were conditioned in warm water (38 ± 2 °C) for 500, 1000, and 1500 h to accelerate the possible degradation induced by a simulated high-moisture exposure environment. The parameters studied were the tensile properties of epoxy resin and CFRP coupons and the fracture energy of the CFRP-concrete interface, which was computed from the CFRP strain measured in the single-lap direct-shear tests using the digital image correlation (DIC) method. Results indicate that both the mechanical properties of the epoxy resin and the CFRP-concrete interface fracture energy were slightly affected by the exposure conditions.
2020
Bond; DIC; Fracture energy; FRP; Hygrothermal ageing
File in questo prodotto:
File Dimensione Formato  
Al-Lami_et_al_2020.pdf

Accesso riservato

: Publisher’s version
Dimensione 12.23 MB
Formato Adobe PDF
12.23 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1131149
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 18
social impact