Diffuse optical imaging can be used to probe highly scattering media like biological tissue down to a depth of few centimeters, with spatial resolution limited by light scattering. Its combination with ultrasound imaging can potentially lead to medical imaging systems with, for instance, high specificity in the examination of tumors. However, the presence of the ultrasound coupling gel between probe and tissue can have detrimental effects on the accuracy of optical imaging techniques. Here we present an experimental study on the effect of ultrasound coupling fluids on diffuse optical spectroscopy (DOS) and diffuse correlation spectroscopy (DCS). We demonstrate on tissue-mimicking phantoms that the use of standard water-clear gels, providing a direct path for the light from the source to the detection point, can distort optical measurements generating strong underestimation of both the absorption and the reduced scattering coefficients in DOS measurements, as well as underestimation of the Brownian diffusion coefficient in DCS measurements. On the contrary, various turbid fluids demonstrate excellent performance in preventing this issue.

Effects of ultrasound impedance matching fluids on diffuse optical measurements

L. Di Sieno;D. Contini;A. Farina;P. Taroni;A. Pifferi;A. Dalla Mora
2019-01-01

Abstract

Diffuse optical imaging can be used to probe highly scattering media like biological tissue down to a depth of few centimeters, with spatial resolution limited by light scattering. Its combination with ultrasound imaging can potentially lead to medical imaging systems with, for instance, high specificity in the examination of tumors. However, the presence of the ultrasound coupling gel between probe and tissue can have detrimental effects on the accuracy of optical imaging techniques. Here we present an experimental study on the effect of ultrasound coupling fluids on diffuse optical spectroscopy (DOS) and diffuse correlation spectroscopy (DCS). We demonstrate on tissue-mimicking phantoms that the use of standard water-clear gels, providing a direct path for the light from the source to the detection point, can distort optical measurements generating strong underestimation of both the absorption and the reduced scattering coefficients in DOS measurements, as well as underestimation of the Brownian diffusion coefficient in DCS measurements. On the contrary, various turbid fluids demonstrate excellent performance in preventing this issue.
2019
Diffuse Optical Spectroscopy and Imaging VII
9781510628410
Diffuse optical spectroscopy, diffuse correlation spectroscopy, ultrasound imaging, light scattering
File in questo prodotto:
File Dimensione Formato  
110742T.pdf

Accesso riservato

Descrizione: fulltext
: Publisher’s version
Dimensione 532.99 kB
Formato Adobe PDF
532.99 kB Adobe PDF   Visualizza/Apri
110742T_with_coverpage.pdf

accesso aperto

Descrizione: fulltext free
: Publisher’s version
Dimensione 877.34 kB
Formato Adobe PDF
877.34 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1115447
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact