The presented work shows the results of the monitoring campaign conducted on two Cross Laminated Timber (CLT) test box equipped respectively with a micro ventilated facade and a thermal coat technology. Specifically, the experimental work was performed in order to compare the temperature levels of the Isotec® wall micro ventilated facade respect to traditional ETICS, with two different thermal mass, for facade insulation. The results showed that the micro ventilated façade, due to the shielding and air cavity comined effect contributes to reduce the summer heat stress with lower internal heat loads.

Experimental analysis of different multilayer insulated façade

graziano salvalai
2018-01-01

Abstract

The presented work shows the results of the monitoring campaign conducted on two Cross Laminated Timber (CLT) test box equipped respectively with a micro ventilated facade and a thermal coat technology. Specifically, the experimental work was performed in order to compare the temperature levels of the Isotec® wall micro ventilated facade respect to traditional ETICS, with two different thermal mass, for facade insulation. The results showed that the micro ventilated façade, due to the shielding and air cavity comined effect contributes to reduce the summer heat stress with lower internal heat loads.
2018
In situ monitoring campaign, Micro ventilate façade, ETIC façade, Performance comparison
File in questo prodotto:
File Dimensione Formato  
Tema Salvalai 2018.pdf

accesso aperto

: Publisher’s version
Dimensione 7.58 MB
Formato Adobe PDF
7.58 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1068032
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact