Over the last decades epidural analgesia has gathered research interest and broad clinical acceptance. In this procedure, the detection of the epidural space is pivotal to avoid major complications. Although, some systems for supporting the anaesthetist in the epidural space detection are commercially available, this difficult procedure is often performed without any support. In previous articles, our research group described a new approach for a non-invasive detection of the epidural space; the assessment of the system was also performed both on a spinal column simulator and in ex vivo animal model (small pig). The mentioned system is based on a Force Sensing Resistor (FSR) that monitors the load exerted by the anaesthesiologist on the syringe plunger during the procedure. The resistance of the sensor is transduced into a voltage by means of a Wheatstone bridge (WB), then it is amplified, finally it is collected by a remote laptop. When the needle reaches the epidural space, the load applied by the anaesthesiologist decreases, so the consequent change of the system output may be used for the detection of the entrance within this space. The previous version of the system communicates to the laptop via USB. In this article, we described a new version of the system which communicates to the laptop via wireless. This solution aims at facilitating the use of the system in clinical settings. After the description of the measuring system, its preliminary assessment in patients undergoing epidural puncture will be reported.

Design and fabrication of a non-invasive, wireless system for monitoring needle insertion during epidural puncture

Schena, E.;Saccomandi, P.;
2018-01-01

Abstract

Over the last decades epidural analgesia has gathered research interest and broad clinical acceptance. In this procedure, the detection of the epidural space is pivotal to avoid major complications. Although, some systems for supporting the anaesthetist in the epidural space detection are commercially available, this difficult procedure is often performed without any support. In previous articles, our research group described a new approach for a non-invasive detection of the epidural space; the assessment of the system was also performed both on a spinal column simulator and in ex vivo animal model (small pig). The mentioned system is based on a Force Sensing Resistor (FSR) that monitors the load exerted by the anaesthesiologist on the syringe plunger during the procedure. The resistance of the sensor is transduced into a voltage by means of a Wheatstone bridge (WB), then it is amplified, finally it is collected by a remote laptop. When the needle reaches the epidural space, the load applied by the anaesthesiologist decreases, so the consequent change of the system output may be used for the detection of the entrance within this space. The previous version of the system communicates to the laptop via USB. In this article, we described a new version of the system which communicates to the laptop via wireless. This solution aims at facilitating the use of the system in clinical settings. After the description of the measuring system, its preliminary assessment in patients undergoing epidural puncture will be reported.
2018
JOURNAL OF PHYSICS. CONFERENCE SERIES
Physics and Astronomy (all)
File in questo prodotto:
File Dimensione Formato  
11311-1067443 Saccomandi.pdf

accesso aperto

: Publisher’s version
Dimensione 656.57 kB
Formato Adobe PDF
656.57 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1067443
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact