Breathing Walls are envelope components, based on porous materials, crossed by a natural or forced airflow. Since they behave both as recovery heat exchangers and active insulation, reducing the conductive heat flux, they represent a promising envelope technology, allowing to reduce energy consumption in buildings. From the modeling point of view, an analytical model can be found in literature, describing heat and mass transfer across Breathing Walls in steady state conditions. However, to the best of the authors' knowledge, the model lacks an exhaustive experimental validation. Therefore, in this paper, the novel laboratory apparatus named Dual Air Vented Thermal Box developed at Politecnico of Milano is presented. The apparatus is used to experimentally investigate the steady state behaviour of a 1 m2 Air Permeable Concrete sample, crossed by an airflow at different velocities up to 12 mm/s. The temperature profile inside the sample, measured in different positions, is compared with the model predictions. While in the central portion of the wall a very good agreement is found, the experimental results at the top and at the bottom of the wall suggest a non-uniform velocity field entering the sample. A qualitative confirmation of this hypothesis is provided by CFD simulations on the apparatus, clearly showing a mixed convection regime on both sides of the wall. The results lead to state the validity of the one-dimensional analytical model in literature, although a careful application should take into account adjusted boundary conditions, consisting in an airflow velocity possibly variable with height.

Experimental investigation of the steady state behaviour of Breathing Walls by means of a novel laboratory apparatus

ALONGI, ANDREA;ANGELOTTI, ADRIANA;MAZZARELLA, LIVIO
2017-01-01

Abstract

Breathing Walls are envelope components, based on porous materials, crossed by a natural or forced airflow. Since they behave both as recovery heat exchangers and active insulation, reducing the conductive heat flux, they represent a promising envelope technology, allowing to reduce energy consumption in buildings. From the modeling point of view, an analytical model can be found in literature, describing heat and mass transfer across Breathing Walls in steady state conditions. However, to the best of the authors' knowledge, the model lacks an exhaustive experimental validation. Therefore, in this paper, the novel laboratory apparatus named Dual Air Vented Thermal Box developed at Politecnico of Milano is presented. The apparatus is used to experimentally investigate the steady state behaviour of a 1 m2 Air Permeable Concrete sample, crossed by an airflow at different velocities up to 12 mm/s. The temperature profile inside the sample, measured in different positions, is compared with the model predictions. While in the central portion of the wall a very good agreement is found, the experimental results at the top and at the bottom of the wall suggest a non-uniform velocity field entering the sample. A qualitative confirmation of this hypothesis is provided by CFD simulations on the apparatus, clearly showing a mixed convection regime on both sides of the wall. The results lead to state the validity of the one-dimensional analytical model in literature, although a careful application should take into account adjusted boundary conditions, consisting in an airflow velocity possibly variable with height.
2017
Air permeable concrete; Breathing wall; Dynamic insulation; Experimental assessment; Laboratory apparatus; Environmental Engineering; Geography, Planning and Development; Civil and Structural Engineering; Building and Construction
File in questo prodotto:
File Dimensione Formato  
BAE_DAVTB_preprint_IRIS.pdf

accesso aperto

: Pre-Print (o Pre-Refereeing)
Dimensione 9.08 MB
Formato Adobe PDF
9.08 MB Adobe PDF Visualizza/Apri