In the paper, the reliability of the Model Code approach for evaluating the bearing capacity of a Steel Fiber Reinforced Concrete (SFRC) elevated slab is discussed with reference to the case of a twostories family house recently built in Italy. To the authors’ knowledge, this is the first realization of SFRC elevated slab in Italy. Six standard notched specimens have been cast and tested through a third point bending test set-up. These tests allowed to classify the fiber reinforced material based on post– cracking residual strengths measured for two different crack openings, respectively related to serviceability and ultimate limit states. In conjunction with the SFRC slab casting, four shallow beams (1.5×0.5×0.25 m) having the same thickness of the slab were cast. The shallow beams have been tested in bending to verify the specific bearing capacity of the slab having used for both the slab and the shallow beams the same casting procedure. After the beam tests, coring procedures have been carried out on the shallow beams in order to measure the SFRC tensile behavior. The cored cylinders were tested with two non-standardized indirect tensile methodologies: Double Edge Wedge Splitting (DEWS) and Double Punch (Barcelona) tests.

Control procedure to check the σ–ω relationship used to design a SFRC slab

MARTINELLI, PAOLO;COLOMBO, MATTEO;DI PRISCO, MARCO
2016-01-01

Abstract

In the paper, the reliability of the Model Code approach for evaluating the bearing capacity of a Steel Fiber Reinforced Concrete (SFRC) elevated slab is discussed with reference to the case of a twostories family house recently built in Italy. To the authors’ knowledge, this is the first realization of SFRC elevated slab in Italy. Six standard notched specimens have been cast and tested through a third point bending test set-up. These tests allowed to classify the fiber reinforced material based on post– cracking residual strengths measured for two different crack openings, respectively related to serviceability and ultimate limit states. In conjunction with the SFRC slab casting, four shallow beams (1.5×0.5×0.25 m) having the same thickness of the slab were cast. The shallow beams have been tested in bending to verify the specific bearing capacity of the slab having used for both the slab and the shallow beams the same casting procedure. After the beam tests, coring procedures have been carried out on the shallow beams in order to measure the SFRC tensile behavior. The cored cylinders were tested with two non-standardized indirect tensile methodologies: Double Edge Wedge Splitting (DEWS) and Double Punch (Barcelona) tests.
2016
FRC: The Modern Landscape. BEFIB 2016. Proceedings of the 9th RILEM International Symposium on Fibre Reinforced Concrete
978-2-35158-187-2
fiber reinforced concrete (FRC); elevated slab; indirect tensile tests; Barcelona test, DEWS test
File in questo prodotto:
File Dimensione Formato  
Paper216_Martinelli_DEWSvs Barcellona.pdf

Accesso riservato

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 276.93 kB
Formato Adobe PDF
276.93 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/998801
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact