Dry-assembled precast concrete frame structures are typically made with dowel beam-to-column connections, which allow relative rotation along the beam direction. In the orthogonal direction the rotation of the beam is prevented but again the connections of the superimposed floor elements allow for relative rotation. All the ductility and energy dissipation demand in case of seismic action is therefore concentrated at the base of cantilever columns. Hence, the column-to-foundation connection plays a key role on the seismic performance of such structures. Mechanical connection devices, even if correctly designed for what concerns resistance, may affect the behaviour of the whole joint modifying the ductility capacity of the columns and their energy dissipation properties. An experimental campaign on different mechanical connection devices has been performed at Politecnico di Milano within the Safecast project (European programme FP7-SME-2007-2, Grant agreement No. 218417, 2009). The results of cyclic tests on full scale structural sub-assembly specimens are presented. Design rules are suggested for each of the tested connections on the basis of the experimental observations, and numerical analyses have been performed with hysteretic parameters calibrated on the experimental loops. The seismic performance of structures provided with those connections is investigated through a case study on a multi-storey precast building prototype, which has also been subject to full-scale pseudo-dynamic testing within the same research project at the European Laboratory of Structural Assessment of the Joint Research Centre of the European Commission. The comparison of the results from the structure provided with the different studied connections clearly highlights how some solutions may lead to both reduction of ductility capacity and dissipation of energy, increasing the expected structural damage and the seismic risk.

Influence of different mechanical column-foundation connection devices on the seismic behaviour of precast structures

DAL LAGO, BRUNO ALBERTO;TONIOLO, GIANDOMENICO;LAMPERTI TORNAGHI, MARCO GIANNI
2016-01-01

Abstract

Dry-assembled precast concrete frame structures are typically made with dowel beam-to-column connections, which allow relative rotation along the beam direction. In the orthogonal direction the rotation of the beam is prevented but again the connections of the superimposed floor elements allow for relative rotation. All the ductility and energy dissipation demand in case of seismic action is therefore concentrated at the base of cantilever columns. Hence, the column-to-foundation connection plays a key role on the seismic performance of such structures. Mechanical connection devices, even if correctly designed for what concerns resistance, may affect the behaviour of the whole joint modifying the ductility capacity of the columns and their energy dissipation properties. An experimental campaign on different mechanical connection devices has been performed at Politecnico di Milano within the Safecast project (European programme FP7-SME-2007-2, Grant agreement No. 218417, 2009). The results of cyclic tests on full scale structural sub-assembly specimens are presented. Design rules are suggested for each of the tested connections on the basis of the experimental observations, and numerical analyses have been performed with hysteretic parameters calibrated on the experimental loops. The seismic performance of structures provided with those connections is investigated through a case study on a multi-storey precast building prototype, which has also been subject to full-scale pseudo-dynamic testing within the same research project at the European Laboratory of Structural Assessment of the Joint Research Centre of the European Commission. The comparison of the results from the structure provided with the different studied connections clearly highlights how some solutions may lead to both reduction of ductility capacity and dissipation of energy, increasing the expected structural damage and the seismic risk.
2016
Precast concrete structures · Seismic performance · Mechanical connections · Column-to-foundation joint · Numerical analysis
File in questo prodotto:
File Dimensione Formato  
DLcol_found060716_REV2.pdf

Accesso riservato

Descrizione: Articolo
: Pre-Print (o Pre-Refereeing)
Dimensione 2.22 MB
Formato Adobe PDF
2.22 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/997958
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 61
  • ???jsp.display-item.citation.isi??? 50
social impact