This paper presents a laboratory-scale experimental investigation of laser cleaning of diagnostic First Mirrors (FMs). Redeposition of contaminants sputtered from tokamak first wall onto FMs surface could dramatically decrease their reflectivity in an unacceptable way for the functioning of the plasma diagnostic systems. Laser cleaning is a promising solution to tackle this issue. In this work, pulsed laser deposition was exploited to produce rhodium films functional as FMs and to deposit onto them carbon contaminants with tailored features, resembling those found in tokamaks. The same laser system was also used to perform laser cleaning experiments by means of a sample handling procedure that allows to clean some cm(2) in few minutes. The cleaning effectiveness was evaluated in terms of specular reflectivity recovery and mirror surface integrity. The effect of different laser wavelengths (lambda = 1064, 266 nm) on the cleaning process is also addressed.
Laser cleaning of diagnostic mirrors from tokamak-like carbon contaminants
MAFFINI, ALESSANDRO;DELLASEGA, DAVID;RUSSO, VALERIA;PERISSINOTTO, STEFANO;PASSONI, MATTEO
2015-01-01
Abstract
This paper presents a laboratory-scale experimental investigation of laser cleaning of diagnostic First Mirrors (FMs). Redeposition of contaminants sputtered from tokamak first wall onto FMs surface could dramatically decrease their reflectivity in an unacceptable way for the functioning of the plasma diagnostic systems. Laser cleaning is a promising solution to tackle this issue. In this work, pulsed laser deposition was exploited to produce rhodium films functional as FMs and to deposit onto them carbon contaminants with tailored features, resembling those found in tokamaks. The same laser system was also used to perform laser cleaning experiments by means of a sample handling procedure that allows to clean some cm(2) in few minutes. The cleaning effectiveness was evaluated in terms of specular reflectivity recovery and mirror surface integrity. The effect of different laser wavelengths (lambda = 1064, 266 nm) on the cleaning process is also addressed.File | Dimensione | Formato | |
---|---|---|---|
Maffini_post print.pdf
Open Access dal 02/08/2016
Descrizione: post print
:
Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione
1.26 MB
Formato
Adobe PDF
|
1.26 MB | Adobe PDF | Visualizza/Apri |
Maffini_JNM15_laser cleaning.pdf
Accesso riservato
Descrizione: articolo principale
:
Publisher’s version
Dimensione
930.44 kB
Formato
Adobe PDF
|
930.44 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.