As relatively new and promising members of the wickless heat pipes family, Pulsating Heat Pipes, with their high effective thermal conductivity, construction simplicity, low weight, and potential high power loads may answer the present industry demand of high heat transfer capability, efficient thermal control, flexibility and low cost. Numerous are the attempts to simulate their complex thermal behavior, but none of the existing models is validated for transient operative conditions and under various gravity levels. Thus, a novel lumped parameters model able to compute the steady state as well as the transient performance of PHPs has been developed. It consists of a two-phase separated flow model applicable to a confined operating regime (slug–plug flow). A complete set of balance differential equations accounts for thermal and fluid-dynamic phenomena. The main originalities of this tool lay in the suppression of the standard assumption of saturated vapor plugs as well as in the consequent embedding of heterogeneous and homogeneous phase changes. In addition, an experimental work has been carried out with a 16 turns copper capillary PHP filled with FC-72. Therefore, the model has been validated in several operative conditions and under various gravity levels by comparison with these experimental data both in normal and hyper-gravity conditions showing very good prediction capability.

Non equilibrium lumped parameter model for Pulsating Heat Pipes: validation in normal and hyper-gravity conditions

DE FALCO, CARLO;ARANEO, LUCIO TIZIANO;
2016-01-01

Abstract

As relatively new and promising members of the wickless heat pipes family, Pulsating Heat Pipes, with their high effective thermal conductivity, construction simplicity, low weight, and potential high power loads may answer the present industry demand of high heat transfer capability, efficient thermal control, flexibility and low cost. Numerous are the attempts to simulate their complex thermal behavior, but none of the existing models is validated for transient operative conditions and under various gravity levels. Thus, a novel lumped parameters model able to compute the steady state as well as the transient performance of PHPs has been developed. It consists of a two-phase separated flow model applicable to a confined operating regime (slug–plug flow). A complete set of balance differential equations accounts for thermal and fluid-dynamic phenomena. The main originalities of this tool lay in the suppression of the standard assumption of saturated vapor plugs as well as in the consequent embedding of heterogeneous and homogeneous phase changes. In addition, an experimental work has been carried out with a 16 turns copper capillary PHP filled with FC-72. Therefore, the model has been validated in several operative conditions and under various gravity levels by comparison with these experimental data both in normal and hyper-gravity conditions showing very good prediction capability.
2016
Pulsating Heat Pipe, Numerical model, Transient mode, Hyper-gravity
File in questo prodotto:
File Dimensione Formato  
HMT_2015_581_Original_V0_MM.pdf

Accesso riservato

Descrizione: Articolo principale in preprint
: Pre-Print (o Pre-Refereeing)
Dimensione 3.31 MB
Formato Adobe PDF
3.31 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/977265
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 15
social impact