This work reports a modeling methodology for the prediction of conducted emissions (CE) in a wide frequency range (up to 100MHz), which are generated by dc/dc converters and propagate along the power buses of satellites. In particular, the dc/dc converter seen as a source of CE is represented by a behavioral model, whose parameters can be identified by two unit-level experimental procedures performed in controlled test setups. A simplified multiconductor transmission-line (MTL) model is developed to account for the propagation of CE in shielded bundles of twisted-wire pairs used as power cables. The whole power system is represented by the interconnection of the circuit models of dc/dc converters, cables, and Power Conditioning and Distribution Unit (PCDU). By solving the obtained network, frequency spectra of CE can be predicted. Experimental results are reported to substantiate the accuracy of the proposed unit-level dc/dc converter model and the MTL model of cables. Finally, a system-level test setup composed of three dc/dc converters connected to a PCDU is considered, and predicted CE are compared versus experimental measurements.

Prediction of conducted emissions in satellite power buses

SPADACINI, GIORDANO;GRASSI, FLAVIA;BELLAN, DIEGO;PIGNARI, SERGIO AMEDEO;
2015-01-01

Abstract

This work reports a modeling methodology for the prediction of conducted emissions (CE) in a wide frequency range (up to 100MHz), which are generated by dc/dc converters and propagate along the power buses of satellites. In particular, the dc/dc converter seen as a source of CE is represented by a behavioral model, whose parameters can be identified by two unit-level experimental procedures performed in controlled test setups. A simplified multiconductor transmission-line (MTL) model is developed to account for the propagation of CE in shielded bundles of twisted-wire pairs used as power cables. The whole power system is represented by the interconnection of the circuit models of dc/dc converters, cables, and Power Conditioning and Distribution Unit (PCDU). By solving the obtained network, frequency spectra of CE can be predicted. Experimental results are reported to substantiate the accuracy of the proposed unit-level dc/dc converter model and the MTL model of cables. Finally, a system-level test setup composed of three dc/dc converters connected to a PCDU is considered, and predicted CE are compared versus experimental measurements.
2015
ELETTRICI
File in questo prodotto:
File Dimensione Formato  
GS+FG+DB+SP+FM_CE_in_satellite.pdf

accesso aperto

Descrizione: Articolo
: Publisher’s version
Dimensione 4.3 MB
Formato Adobe PDF
4.3 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/973898
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 10
social impact