Windows are the most important part of the building façade to control solar gains, thermal losses and visual comfort. Office buildings usually have medium-high WWR (window to wall ratio value) and high internal gains (due to users, lighting and appliances). For this reason, they require a good balance between thermal and visible performances of transparent façades and shading control strategies to avoid overheating, optimizing daylighting aspects. A sensitivity analysis was assessed to evaluate primary energy use for heating, lighting and cooling for conventional Italian single office units equipped with static metal mesh shading devices with different geometries and openness factor values. Different location (Milan, Palermo), orientation (south and west) and WWR (33% and 100%) were analyzed. Hence shading devices alternatives as venetian blinds and sun control windows are proposed as a comparison.

Metal Mesh as Shading Devices and Thermal Response of an Office Building: Parametric Analysis

MAININI, ANDREA GIOVANNI;POLI, TIZIANA;SPERONI, ALBERTO
2015-01-01

Abstract

Windows are the most important part of the building façade to control solar gains, thermal losses and visual comfort. Office buildings usually have medium-high WWR (window to wall ratio value) and high internal gains (due to users, lighting and appliances). For this reason, they require a good balance between thermal and visible performances of transparent façades and shading control strategies to avoid overheating, optimizing daylighting aspects. A sensitivity analysis was assessed to evaluate primary energy use for heating, lighting and cooling for conventional Italian single office units equipped with static metal mesh shading devices with different geometries and openness factor values. Different location (Milan, Palermo), orientation (south and west) and WWR (33% and 100%) were analyzed. Hence shading devices alternatives as venetian blinds and sun control windows are proposed as a comparison.
2015
Metal Mesh, Shading devices, Energy efficiency, Office, Building Envelope, Angular solar and visible transmittance measurements
File in questo prodotto:
File Dimensione Formato  
Metal mesh 2015.pdf

accesso aperto

: Publisher’s version
Dimensione 439.07 kB
Formato Adobe PDF
439.07 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/972284
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact