In this paper, debonding phenomena between carbon fiber reinforced polymer (CFRP) strips and masonry support were investigated on the basis of single-lap shear tests, considering different dimensions of the bond length. To capture the post-peak response of the CFRP–masonry joint, the slip between the support and the reinforcement strip was controlled using a clip gauge positioned at the end of the reinforcement. The tests were simulated by means of a finite element model able to capture the post-peak snap-back behavior due to the failure process. The numerical model is based on zero-thickness interface elements and on a proper non-linear cohesive law. The comparison between experimental and numerical results was performed in terms of overall response, measured by both the machine stroke and the clip gauge positioned at the free end of the reinforcement. The cases of effective bond length greater and lesser than the minimum anchorage length, suggested by the CNR Italian recommendation, were considered.

Pull out of FRP reinforcement from masonry pillars: Experimental and numerical results

BARBIERI, GAIA;BIOLZI, LUIGI;BOCCIARELLI, MASSIMILIANO;CATTANEO, SARA
2015-01-01

Abstract

In this paper, debonding phenomena between carbon fiber reinforced polymer (CFRP) strips and masonry support were investigated on the basis of single-lap shear tests, considering different dimensions of the bond length. To capture the post-peak response of the CFRP–masonry joint, the slip between the support and the reinforcement strip was controlled using a clip gauge positioned at the end of the reinforcement. The tests were simulated by means of a finite element model able to capture the post-peak snap-back behavior due to the failure process. The numerical model is based on zero-thickness interface elements and on a proper non-linear cohesive law. The comparison between experimental and numerical results was performed in terms of overall response, measured by both the machine stroke and the clip gauge positioned at the free end of the reinforcement. The cases of effective bond length greater and lesser than the minimum anchorage length, suggested by the CNR Italian recommendation, were considered.
2015
Carbon fiber; Fracture; Finite element analysis (FEA); Mechanical testing; Snap-back
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1359836814004818-main.pdf

Accesso riservato

: Publisher’s version
Dimensione 3.85 MB
Formato Adobe PDF
3.85 MB Adobe PDF   Visualizza/Apri
Pull out of FRP reinforcement from masonry pillars_11311-887556_Barbieri.pdf

accesso aperto

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 3.74 MB
Formato Adobe PDF
3.74 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/887556
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 13
social impact