Aortic interleaflet triangle reshaping (AITR) is a surgical approach to aortic valve incontinence that involves placing three stitches at half of the interleaflet triangles height. In this work, the relationship between the actual stitch height and valve functioning, and the safety margin that the surgeon can rely on in applying the stitches were systematically investigated in vitro. AITR surgery was applied to six swine aortic roots placing the stitches empirically at 50\%, 60\% and 75\% of the triangle heights. Then the actual stitch heights were measured and the hydrodynamic performances were evaluated with a pulsatile hydrodynamic mock loop. Actual stitch heights were 45��2\% 61��4\% and 79��6\%. As compared to untreated conditions, the 50\% configuration induced a significant variation in the effective orifice area. With stitches placed at 60\%, the mean systolic pressure drop increased significantly with respect to the untreated case, but no significant changes were recorded with respect to the 50\% configuration. At 75\%, all the hydrodynamic parameters of systolic valve functioning worsened significantly. Summarizing, the AITR technique, when performed in a conservative manner did not induce significant alterations in the hydrodynamics of the aortic root in vitro, while more aggressive configurations did. The absence of a statistically significant difference between the 50\% and 60\% configurations suggests that there is a reasonably limited risk of inducing valve stenosis in the post-op scenario due to stitch misplacement.

In vitro study of the Aortic Interleaflet Triangle Reshaping

VISMARA, RICCARDO;LEOPALDI, ALBERTO MARIA;MANGINI, ANDREA;FIORE, GIANFRANCO BENIAMINO
2014-01-01

Abstract

Aortic interleaflet triangle reshaping (AITR) is a surgical approach to aortic valve incontinence that involves placing three stitches at half of the interleaflet triangles height. In this work, the relationship between the actual stitch height and valve functioning, and the safety margin that the surgeon can rely on in applying the stitches were systematically investigated in vitro. AITR surgery was applied to six swine aortic roots placing the stitches empirically at 50\%, 60\% and 75\% of the triangle heights. Then the actual stitch heights were measured and the hydrodynamic performances were evaluated with a pulsatile hydrodynamic mock loop. Actual stitch heights were 45��2\% 61��4\% and 79��6\%. As compared to untreated conditions, the 50\% configuration induced a significant variation in the effective orifice area. With stitches placed at 60\%, the mean systolic pressure drop increased significantly with respect to the untreated case, but no significant changes were recorded with respect to the 50\% configuration. At 75\%, all the hydrodynamic parameters of systolic valve functioning worsened significantly. Summarizing, the AITR technique, when performed in a conservative manner did not induce significant alterations in the hydrodynamics of the aortic root in vitro, while more aggressive configurations did. The absence of a statistically significant difference between the 50\% and 60\% configurations suggests that there is a reasonably limited risk of inducing valve stenosis in the post-op scenario due to stitch misplacement.
2014
Aortic valve; In vitro tests; Interleaflet triangle reshaping; Reparative surgery
File in questo prodotto:
File Dimensione Formato  
In vitro study of the Aortic Interleaflet Triangle Reshaping_11311-762826_Fiore.pdf

accesso aperto

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 580.61 kB
Formato Adobe PDF
580.61 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/762826
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 11
social impact