In this paper the strength of the interface between SMA reinforcements and host composite of a hybrid laminated composite, proposed for the lateral horns of a railway collector, will be studied in details by means of pull-out tests. The effect of the geometrical pattern of the SMA sheets and of the texturing of its surface on the load transfer capacity of the interface is investigated.
STRENGTH OF SMA/GFRP INTERFACE IN A NEW DESIGNED RAILWAY COLLECTOR
BOCCIOLONE, MARCO FRANCESCO;CARNEVALE, MARCO;COLLINA, ANDREA;LECIS, NORA FRANCESCA MARIA;LO CONTE, ANTONIETTA;PREVITALI, BARBARA;
2013-01-01
Abstract
In this paper the strength of the interface between SMA reinforcements and host composite of a hybrid laminated composite, proposed for the lateral horns of a railway collector, will be studied in details by means of pull-out tests. The effect of the geometrical pattern of the SMA sheets and of the texturing of its surface on the load transfer capacity of the interface is investigated.File in questo prodotto:
File | Dimensione | Formato | |
---|---|---|---|
2013SMART.pdf
Accesso riservato
:
Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione
698.59 kB
Formato
Adobe PDF
|
698.59 kB | Adobe PDF | Visualizza/Apri |
SMART2013_PROGRAM_FINAL.pdf
Accesso riservato
:
Altro materiale allegato
Dimensione
202.1 kB
Formato
Adobe PDF
|
202.1 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.