Oil-water two-phase flow experiments were conducted in a horizontal duct made of Plexiglas to determine the holdup of oil by means of the quick closing valves technique, using mineral oil (viscosity: 0.838 Pa s at 20 °C; density: 890 kg m-3) and tap Water. The duct presents a sudden contraction, with contraction ratio of 0.64. about 200 tests were performed by varying the flow rates of the phases. Flow patterns were investigated for both the up- and downstream pipe. Due to the relatively high value of the contraction ratio, it was not observed any relevant variation of the flow patterns across the sudden contraction. Data were then compared with predictions of a specific correlation for oil-water flow and some correlations for gas-water flow. A drift-flux model was also applied to determine the distribution parameter. The results agree quite well with flow pattern visualization.

Measurement of the oil holdup for a two-phase oil-water flow through a sudden contraction in a horizontal pipe

COLOMBO, LUIGI PIETRO MARIA;GUILIZZONI, MANFREDO GHERARDO;SOTGIA, GIORGIO MARCO;
2013-01-01

Abstract

Oil-water two-phase flow experiments were conducted in a horizontal duct made of Plexiglas to determine the holdup of oil by means of the quick closing valves technique, using mineral oil (viscosity: 0.838 Pa s at 20 °C; density: 890 kg m-3) and tap Water. The duct presents a sudden contraction, with contraction ratio of 0.64. about 200 tests were performed by varying the flow rates of the phases. Flow patterns were investigated for both the up- and downstream pipe. Due to the relatively high value of the contraction ratio, it was not observed any relevant variation of the flow patterns across the sudden contraction. Data were then compared with predictions of a specific correlation for oil-water flow and some correlations for gas-water flow. A drift-flux model was also applied to determine the distribution parameter. The results agree quite well with flow pattern visualization.
2013
Atti del XXXI Congresso Nazionale UIT sulla Trasmissione del Calore
97888-6493-017-6
File in questo prodotto:
File Dimensione Formato  
UIT2013_CGSBP.pdf

Accesso riservato

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 756.76 kB
Formato Adobe PDF
756.76 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/756249
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 4
social impact