In this work, the melt fracture behavior of microfilled polymer melts based on a high-density polyethylene (HDPE) was investigated by means of a capillary rheometer, which operated at constant piston velocity. The microfilled melts examined had the same filler content (10 vol%), but differed for the type of filler (glass beads, discontinuous glass fibers, and talc). The results demonstrated that the presence of rigid fillers influences the melt fracture behavior of the filled melts in a way that is dependent on the type of filler dispersed in the HDPE melt. Opposite effects were induced by lamellar particles of talc and by glass fillers (either beads or fibers): the former promoted flow stability, whereas the latter fostered the occurrence of instabilities of ‘‘stick-slip’’ type. The effects induced by the presence of the glass fillers on the oscillating flow that takes place when ‘‘stick-slip’’ instabilities occur were also analyzed and discussed.

Experimental Study of the Melt Fracture Behavior of Filled High-Density Polyethylene Melts

BRIATICO VANGOSA, FRANCESCO;
2013-01-01

Abstract

In this work, the melt fracture behavior of microfilled polymer melts based on a high-density polyethylene (HDPE) was investigated by means of a capillary rheometer, which operated at constant piston velocity. The microfilled melts examined had the same filler content (10 vol%), but differed for the type of filler (glass beads, discontinuous glass fibers, and talc). The results demonstrated that the presence of rigid fillers influences the melt fracture behavior of the filled melts in a way that is dependent on the type of filler dispersed in the HDPE melt. Opposite effects were induced by lamellar particles of talc and by glass fillers (either beads or fibers): the former promoted flow stability, whereas the latter fostered the occurrence of instabilities of ‘‘stick-slip’’ type. The effects induced by the presence of the glass fillers on the oscillating flow that takes place when ‘‘stick-slip’’ instabilities occur were also analyzed and discussed.
2013
HDPE melts; melt fracture; capillary rheometer; High pressure dilatometry
File in questo prodotto:
File Dimensione Formato  
Experimantal study of melt fractue behavior of filled high-Density Polyethylene melts.pdf

Accesso riservato

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 1.07 MB
Formato Adobe PDF
1.07 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/731985
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 17
social impact