The heat transfer coefficients between radiant surfaces and room are influenced by several parameters: surfaces temperature distributions, internal gains, air movements. The aim of this paper is to evaluate the heat transfer coefficients between radiant ceiling and room in typical conditions of occupancy of an office or residential building. Internal gains were therefore simulated using heated cylinders and heat losses using cooled surfaces. Evaluations were developed by means of experimental tests in an environmental chamber. Heat transfer coefficient may be expressed separately for radiation and convection or as one total parameter, but this choice may lead to different considerations about thermal performance of the system. In order to perform correct evaluations, it is therefore extremely important to use the proper reference temperature. The obtained values confirm tendencies found in the literature, indicating limitations and possibilities of radiant ceiling systems improvement.
Experimental evaluation of heat transfer coefficients between radiant ceiling and room
CAUSONE, FRANCESCO;
2009-01-01
Abstract
The heat transfer coefficients between radiant surfaces and room are influenced by several parameters: surfaces temperature distributions, internal gains, air movements. The aim of this paper is to evaluate the heat transfer coefficients between radiant ceiling and room in typical conditions of occupancy of an office or residential building. Internal gains were therefore simulated using heated cylinders and heat losses using cooled surfaces. Evaluations were developed by means of experimental tests in an environmental chamber. Heat transfer coefficient may be expressed separately for radiation and convection or as one total parameter, but this choice may lead to different considerations about thermal performance of the system. In order to perform correct evaluations, it is therefore extremely important to use the proper reference temperature. The obtained values confirm tendencies found in the literature, indicating limitations and possibilities of radiant ceiling systems improvement.File | Dimensione | Formato | |
---|---|---|---|
ScienceDirect ENB2560.pdf
Accesso riservato
Descrizione: published version
:
Publisher’s version
Dimensione
272.64 kB
Formato
Adobe PDF
|
272.64 kB | Adobe PDF | Visualizza/Apri |
Accepted Manuscipt_ENB2560.pdf
accesso aperto
Descrizione: accepted manuscript
:
Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione
383.22 kB
Formato
Adobe PDF
|
383.22 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.