In Mexico efforts are being made to promote the use of solar energy for cooling in the Agro-Food Industries (AFI), 120 industries were contacted in order to assess the solar cooling potential application in the sector. One case study was selected among the visited potential end users according to the size of the facility, the information available and their willingness to collaborate in the present project. Data from the industry was used to select the appropriate solar cooling concept and therefore the collector’s typology, and the absorption cooling system. Moreover, the operation of the system was simulated in order to define the optimal size of the collector field required. The proposed cooling system was composed by a Fresnel concentrating collector field to activate a series of air cooled single-effect ammonia–water absorption chillers. The cooling system simulation was carried out with the Transient Systems Simulation Programme (TRNSYS) which allowed to model the collector system that fulfill the required load. The calculated saved electricity was around 19% of the total consumption, this small fraction is due to the fact that the selected facility is operating continuously with very large refrigeration capacities. The specifications of the simulated solar cooling system are presented.

Solar cooling in the food industry in Mexico: A case study

SCOCCIA, ROSSANO;MOTTA, MARIO
2013-01-01

Abstract

In Mexico efforts are being made to promote the use of solar energy for cooling in the Agro-Food Industries (AFI), 120 industries were contacted in order to assess the solar cooling potential application in the sector. One case study was selected among the visited potential end users according to the size of the facility, the information available and their willingness to collaborate in the present project. Data from the industry was used to select the appropriate solar cooling concept and therefore the collector’s typology, and the absorption cooling system. Moreover, the operation of the system was simulated in order to define the optimal size of the collector field required. The proposed cooling system was composed by a Fresnel concentrating collector field to activate a series of air cooled single-effect ammonia–water absorption chillers. The cooling system simulation was carried out with the Transient Systems Simulation Programme (TRNSYS) which allowed to model the collector system that fulfill the required load. The calculated saved electricity was around 19% of the total consumption, this small fraction is due to the fact that the selected facility is operating continuously with very large refrigeration capacities. The specifications of the simulated solar cooling system are presented.
2013
Greenhouse gas emissions; Agro-Food Industries; Solar cooling; Absorption
File in questo prodotto:
File Dimensione Formato  
ATE3933.pdf

Accesso riservato

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 789.82 kB
Formato Adobe PDF
789.82 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/708934
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 19
social impact