In the paper some case studies of damaged towers in Italy are presented: the Tower Masserano of palace Ferrero - La Marmora at Biella, the bell tower of the Collegiata of San Vittore at Arcisate, and three medieval towers in Alba. A methodology is put forward for combining laboratory and non-destructive testing methods with monitoring systems in order to reach the goal of evaluating the state of conservation of historic towers and its evolution in time.

Monitoring structural integrity of historic towers:a mixed approach for their damage evaluation

ANZANI, ANNA;BINDA, LUIGIA;
2008-01-01

Abstract

In the paper some case studies of damaged towers in Italy are presented: the Tower Masserano of palace Ferrero - La Marmora at Biella, the bell tower of the Collegiata of San Vittore at Arcisate, and three medieval towers in Alba. A methodology is put forward for combining laboratory and non-destructive testing methods with monitoring systems in order to reach the goal of evaluating the state of conservation of historic towers and its evolution in time.
2008
Structural Faults & Repair 2008
0947644830
Historic towers, brick and stone masonry, crack pattern, diagnosis
File in questo prodotto:
File Dimensione Formato  
13-SFR 2008 Lacid.pdf

Accesso riservato

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 1.16 MB
Formato Adobe PDF
1.16 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/689090
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact