In a three-phase system with isolated neutral ferroresonance is a periodic displacement of the neutral potential. These so called relaxation oscillations are caused by discharging and recharging of the capacitances to the ground via magnetising inductances of e.g. single-pole insulated voltage transformers and the periodic repetition of this process. As a consequence, high saturation currents flow through the primary windings of the voltage transformers heating up these windings and often leading to the destruction of the voltage transformer. The non-linear phase-to-ground inductance of voltage transformers and the phase-to-ground capacitance form an oscillatory circuit which may be kicked on by a switching event, e.g. an earth-fault followed by a self-extinction of the fault current. The present paper specifically investigates the possible occurrence of ferroresonance in power stations where a generator circuit-breaker is employed. The effects of harmonic distortion due to ferroresonance are thoroughly investigated and different mitigation measures are analysed.

Harmonic distortion in power stations due to ferroresonance

DELFANTI, MAURIZIO;PALAZZO, MIRKO;ZICH, RICCARDO
2012-01-01

Abstract

In a three-phase system with isolated neutral ferroresonance is a periodic displacement of the neutral potential. These so called relaxation oscillations are caused by discharging and recharging of the capacitances to the ground via magnetising inductances of e.g. single-pole insulated voltage transformers and the periodic repetition of this process. As a consequence, high saturation currents flow through the primary windings of the voltage transformers heating up these windings and often leading to the destruction of the voltage transformer. The non-linear phase-to-ground inductance of voltage transformers and the phase-to-ground capacitance form an oscillatory circuit which may be kicked on by a switching event, e.g. an earth-fault followed by a self-extinction of the fault current. The present paper specifically investigates the possible occurrence of ferroresonance in power stations where a generator circuit-breaker is employed. The effects of harmonic distortion due to ferroresonance are thoroughly investigated and different mitigation measures are analysed.
2012
2012 Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC),
9781457715587
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/667559
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact