A measurement system and a procedure for the postprocessing of themeasurement data are designed and implemented for onsite characterization of the staticmagnetic field generated by large inductors installed along the railway infrastructure.The measurement procedure allows for simultaneous monitoring of the dc current through the inductor and the resulting magnetic flux density on a radial spatial grid, during normal operating conditions of the railway system. Linear regression is used to identify the parameters of a field model that correlates themagnetic field with the current through the coils. A field map in the space region around the inductor is derived and used both to assess exposure limits for individuals and to identify exclusion zones to prevent inadvertent harmful exposure. Particularly, the minimum distance from the coil axis, complying with the ICNIRP safety requirements for people with implanted electronic medical devices (e.g., pacemakers), is determined and related to the dc current through the filter.
Measurement and assessment of exposure limits for the static magnetic field generated by large inductors for railway applications
PIGNARI, SERGIO AMEDEO;SPADACINI, GIORDANO;
2011-01-01
Abstract
A measurement system and a procedure for the postprocessing of themeasurement data are designed and implemented for onsite characterization of the staticmagnetic field generated by large inductors installed along the railway infrastructure.The measurement procedure allows for simultaneous monitoring of the dc current through the inductor and the resulting magnetic flux density on a radial spatial grid, during normal operating conditions of the railway system. Linear regression is used to identify the parameters of a field model that correlates themagnetic field with the current through the coils. A field map in the space region around the inductor is derived and used both to assess exposure limits for individuals and to identify exclusion zones to prevent inadvertent harmful exposure. Particularly, the minimum distance from the coil axis, complying with the ICNIRP safety requirements for people with implanted electronic medical devices (e.g., pacemakers), is determined and related to the dc current through the filter.File | Dimensione | Formato | |
---|---|---|---|
TEMC 2011 - SP+GS+EF - Measurement and Assessment of.pdf
Accesso riservato
:
Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione
754.37 kB
Formato
Adobe PDF
|
754.37 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.