Here we report an experimental in situ analysis of internal gas crossover leakage in single high- temperature polymer electrolyte membrane fuel cells. The study is based on the analysis of the exhausts from the anode and the cathode of the fuel cell during operation. An abnormal crossover rate across the membrane of the investigated fuel cell was detected, indicating the presence of an internal leakage. The internal flux shows linear dependence on the pressure difference between fuel cell compartments, attesting for permeation as the driving force. When the average cathode pressure is higher than the anode pressure, air crossover is measured. Conversely, hydrogen crossover is measured when the anode pres- sure is higher than the cathode. The effects on fuel cell performance are evaluated under air or hydrogen crossover conditions. Under both conditions, crossover leakage causes a significant increase in hydrogen consumption that reduces fuel recovery from anode exhaust.
Gas crossover leakage in high temperature polymer electrolyte fuel cells: In situ quantification and effect on performance
GALBIATI, SAMUELE;BARICCI, ANDREA;CASALEGNO, ANDREA;MARCHESI, RENZO
2012-01-01
Abstract
Here we report an experimental in situ analysis of internal gas crossover leakage in single high- temperature polymer electrolyte membrane fuel cells. The study is based on the analysis of the exhausts from the anode and the cathode of the fuel cell during operation. An abnormal crossover rate across the membrane of the investigated fuel cell was detected, indicating the presence of an internal leakage. The internal flux shows linear dependence on the pressure difference between fuel cell compartments, attesting for permeation as the driving force. When the average cathode pressure is higher than the anode pressure, air crossover is measured. Conversely, hydrogen crossover is measured when the anode pres- sure is higher than the cathode. The effects on fuel cell performance are evaluated under air or hydrogen crossover conditions. Under both conditions, crossover leakage causes a significant increase in hydrogen consumption that reduces fuel recovery from anode exhaust.File | Dimensione | Formato | |
---|---|---|---|
Gas crossover leakage in high temperature polymer electrolyte fuelcells In situ quantification and effect on performance.pdf
Accesso riservato
:
Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione
343.83 kB
Formato
Adobe PDF
|
343.83 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.