A computational study of a novel passive micromixer is presented. In this work, we analysed a Clo-plus micromixer designed to achieve efficient mixing and characterized by a process of construction that can use a single planar soft lithography step. Mixing studies were carried out at different Reynolds numbers ranging from 1 to 100. The preliminary results suggest that at Re> 50, the Clo-plus micromixer is characterized by a good mixing because of stronger Dean secondary flow and recirculation effect.

Analysis of mixing of a clothoid based passive micromixer: A numerical study

RASPONI, MARCO;
2011-01-01

Abstract

A computational study of a novel passive micromixer is presented. In this work, we analysed a Clo-plus micromixer designed to achieve efficient mixing and characterized by a process of construction that can use a single planar soft lithography step. Mixing studies were carried out at different Reynolds numbers ranging from 1 to 100. The preliminary results suggest that at Re> 50, the Clo-plus micromixer is characterized by a good mixing because of stronger Dean secondary flow and recirculation effect.
2011
Computational Vision and Medical Image Processing: VipIMAGE 2011
9780415683951
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/636896