This work investigates the sensitivity of LES to a rotation of the usual stream-aligned system of coordinates in the case of channel ow at Reτ=180. In the new reference system the principal axes are not necessarily aligned with the streamwise and the spanwise directions: consequently the mean pressure gradient has two different components. Two different codes and different SGS models have been tested in order to evaluate the sensitivity of the alignment of the grid with the mean stream and the coherent wall structures.
LES of the channel flow in a non aligned system of coordinates
ABBA', ANTONELLA;
2011-01-01
Abstract
This work investigates the sensitivity of LES to a rotation of the usual stream-aligned system of coordinates in the case of channel ow at Reτ=180. In the new reference system the principal axes are not necessarily aligned with the streamwise and the spanwise directions: consequently the mean pressure gradient has two different components. Two different codes and different SGS models have been tested in order to evaluate the sensitivity of the alignment of the grid with the mean stream and the coherent wall structures.File in questo prodotto:
File | Dimensione | Formato | |
---|---|---|---|
1742-6596_318_4_042041.pdf
Accesso riservato
:
Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione
484.94 kB
Formato
Adobe PDF
|
484.94 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.