Mechanical calibration and alignment are fundamental steps in the development of any new aerial photogrammetric scanner. One aim of a film scanner in the digital era is to digitise the accumulated historic archives of images belonging to photogrammetric institutes. The present analysis is centred on a scanner with a translating 2D array camera. Two phases of equal importance can be outlined: the first phase is the alignment of all the mechanical parts inside the scanner, and the second is mechanical calibration, when the systematic effects in the camera positioning are measured and compensated. Among the design requirements of this scanner was to avoid the need for geometrical modification of the scanned images: they should be acquired in the correct position and not require a posteriori correction with a software routine. The proposed solutions lead to a final result of a metrologically satisfactory scanner with a geometric uncertainty of 2 lm or less throughout the frame (250mm· 250 mm), a value definitely smaller than the pixel size (10 lm/pixel)

Mechanical calibration and alignment of an aerial photogrammetric film scanner based on a 2d array camera

COMOLLI, LORENZO;SALA, REMO
2010-01-01

Abstract

Mechanical calibration and alignment are fundamental steps in the development of any new aerial photogrammetric scanner. One aim of a film scanner in the digital era is to digitise the accumulated historic archives of images belonging to photogrammetric institutes. The present analysis is centred on a scanner with a translating 2D array camera. Two phases of equal importance can be outlined: the first phase is the alignment of all the mechanical parts inside the scanner, and the second is mechanical calibration, when the systematic effects in the camera positioning are measured and compensated. Among the design requirements of this scanner was to avoid the need for geometrical modification of the scanned images: they should be acquired in the correct position and not require a posteriori correction with a software routine. The proposed solutions lead to a final result of a metrologically satisfactory scanner with a geometric uncertainty of 2 lm or less throughout the frame (250mm· 250 mm), a value definitely smaller than the pixel size (10 lm/pixel)
2010
File in questo prodotto:
File Dimensione Formato  
Comolli,Sala,Mechanical calibration and alignment of Flyscan.pdf

Accesso riservato

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 1.08 MB
Formato Adobe PDF
1.08 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/574088
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 3
social impact